delta
due DY-5121 - User manual
42
25
Modbus/TCP idle timeout
0...65535 (s)
Default 60 seconds
0
Disabled
1...65525
Enabled
26
Baudrate
2400...115200
2400
2400 bps
4800
4800 bps
9600
9600 bps
Default value
19200
19200 bps
38400
38400 bps
57600
57600 bps
115200
115200 bps
27
Parity
0...2
0
No parity
Default
1
Even parity
2
Odd parity
28
Number of Stop bits
1...2
Default 1 stop bit
29
Slave timeout time
25...65535 (ms)
Default 1000 ms
30
Physical interface
0...2
0
EIA-485 (screw
terminals)
Default
1
EIA-232 (DSUB)
2
EIA-232 (screw
terminals)
Authentication
31
Valid IP address 1
0...255
First byte of IP address
0
Disabled
IP address auth disabled
1...255
Enabled
32
Valid IP address 2
0...255
Enabled
Second byte of IP address
33
Valid IP address 3
0...255
Enabled
Third byte of IP address
34
Valid IP address 4
0...255
Enabled
Fourth byte of IP address
35
Mask for Valid IP address 1
0...255
Enabled
First byte of mask
36
Mask for Valid IP address 2
0...255
Enabled
Second byte of mask
37
Mask for Valid IP address 3
0...255
Enabled
Third byte of mask
38
Mask for Valid IP address 4
0...255
Enabled
Fourth byte of mask