Chapter 5 - Module Setup
35
Auto update value and status - This feature is only used for the extra webserver
port. To limit the amount of data transferred and increase speed when using low
bandwith, i.e. modem connection, the data and values could be set to be updated
by clicking the refresh button only. This button is shown at the upper right corner
of the user interface.
Automatic logout time - Defines the time-interval before a user is logged out
from the web-server.
WARNING
If domain name is used make sure that the DNS setting for the Ethernet
connection is correct.
Notes: 1. The webserver always listen to port 80.
When using modem connection, compression on web pages will always be
enabled and Auto update will always be disabled to improve response time,
and the refresh button has to be clicked to update values and status.
2
Changing the Webserver port will disable Webserver on default port 80.
5-8
Ethernet (TCP/IP) settings
If you press the Configuration/Network link you will be presented with the following view:
On this page you can view and change the TCP/IP network settings in the module.
These settings are the same as the ones set by the NetBiter Config utility.