Command Line Interface
Serial Interfacing Commands
DPORT
29
www.arwestcom.com
In the Frequency Hoping mode, the Frequency Pattern generator must generate the random numbers
smaller than the number of frequencies listed in the unit's frequency list.
3.3. Serial Interfacing Commands
3.3.1. DPORT
The DPORT is an object that responsible for data port interface configurations like Bit Rate, Flow
Control, etc.
DPORT [Parameter Name] [Parameters List] [/?]
3.3.2. MPORT
The MPORT is an object that responsible for maintenance serial port interface configurations such as data
rate and number of bits in a byte.
MPORT [Parameter Name] [Parameters List] [/?]
Parameter Name
Parameter List
RATE
0 – Maintenance Port baud rate, a default setting
1 – 1200 baud
2 – 2400 baud
3 – 4800 baud
4 – 9600 baud
5 – 14400 baud
6 – 19200 baud
7 – 38400 baud
8 – 57600 baud
9 – 115200 baud, a default setting
BITS
Set number of bits in one byte (8 or 7)
8 is a default setting
PARITY
0 – None, a default setting
1 – Odd
2 – Even
FLOW
0 – None, a default setting
1 – Not used
2 – HW (RTS/CTS)
Parameter Name
Parameter List
RATE
0 – Auto.
1 – 1200 baud
2 – 2400 baud
3 – 4800 baud
4 – 9600 baud
5 – 14400 baud
6 – 19200 baud
7 – 38400 baud
8 – 57600 baud
9 – 115200 baud, a default setting
Summary of Contents for alphawave AW400