artisan 5400-E User Manual Download Page 1

Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is the sole and 
exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of Artisan Controls 
Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property

Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ  07869

www.artisancontrols.com

5400-

E Event Controller User’s Manual

Table of Contents

Page 1

V1.05

SCREENS & FUNCTIONS

Table Of Contents

INTRODUCTION

. . . . Main Screen

2

2
2
3
4
5
6
7
8
9

10
11
12

13
13
14
15

. . . . Setting Time & Date

. . . . Schedules
. . . . Schedule Editing

TECHNICAL DATA

. . . . Dimensions

. . . . Wiring
. . . . Specifications

. . . . Event Editing
. . . . Schedule Copy & Delete

. . . . Configuring Security & Outputs
. . . . USB Import & Export

. . . . Holidays

. . . . Main Menu

. . . . System Inputs & Outputs

Summary of Contents for 5400-E

Page 1: ...luding court costs and attorney fees being assessed against the party misusing this property Artisan Controls Corporation 111 Canfield Ave Bldg B15 18 Randolph NJ 07869 www artisancontrols com 5400 E...

Page 2: ...splay and includes two relay contact outputs two DC outputs for driving solid state relays two switch inputs and a USB port for importing and exporting the controller configurations MAIN SCREEN The ma...

Page 3: ...touch the item and it toggles back and forth Output Buttons Touching any of the output buttons displays the events in its schedule this event occurs at 7 00 am the output is turned ON and this happen...

Page 4: ...nts Page 4 V1 05 MAIN MENU If password security has been enabled the access code entry window below will appear requesting the 4 digit code This screen will show the digits as asterisks for security P...

Page 5: ...with on your 4950 This one controller can perform all the function of the 4950B bell controller 4950H event controller and all controllers derived from those products SCHEDULES Important Features 1 An...

Page 6: ...f Contents Page 6 V1 05 SCHEDULE EDITING Once you select the output to edit its schedule is displayed in the window to the right All the events are sorted and shown in sequence the up and down arrows...

Page 7: ...ed ON Output turns ON when the event is activated OFF Output turns OFF when the event is activated Event Duration The event duration determines how long the output stays in that state 1 An event durat...

Page 8: ...e you want to copy from and it turns green if it has a schedule Then press the output button you want to copy the schedule to and it highlights If the from output has events and there are enough event...

Page 9: ...0 E controller allows you to enter up to 15 holidays On a holiday all output schedules are disabled and the outputs will be turned off from midnight to midnight Press the Holidays button and the windo...

Page 10: ...to change it from ON to OFF and vice versa Pressing the Edit button opens the access code window to change the current access code Enter the four digits you want and then press ENTER The Clear button...

Page 11: ...ress the USB button in the main menu and this window appears NOTE Do not insert the USB drive until you are in this window Once you insert the USB drive the controller indicates that it has detected i...

Page 12: ...the main menu allows the user to check the proper functioning of the controller outputs and inputs and also allows clearing the entire controller configuration back to the factory defaults You must p...

Page 13: ...uplication misuse or conversion of this information without theexpress written consent of Artisan Controls Corporation is illegaland will result in damages including court costs and attorney fees bein...

Page 14: ...onsent of Artisan Controls Corporation is illegaland will result in damages including court costs and attorney fees being assessed against the party misusing this property Artisan Controls Corporation...

Page 15: ...t inputs 5mA 5VDC OUTPUTS OUT1 OUT2 SPNO relay contacts rated 10A 125V 7A 250V OUT3 OUT4 5VDC 50mA maximum2 FUNCTIONALITY Up to 128 events usable for any output configurable for any number of days of...