artisan 5400-E User Manual Download Page 11

Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is the sole and 
exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written consent of Artisan Controls 
Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party misusing this property

Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ  07869

www.artisancontrols.com

5400-

E Event Controller User’s Manual

Table of Contents

Page 11

V1.05

The 5400-E can save and read information from USB flash 
drives up to 16Gb in size. Press the [USB] button in the main 
menu and this window appears.

NOTE: Do not insert the USB drive until you are in this window.

Once you insert the USB drive the controller indicates that it 
has detected it and the [Export] and [Import] buttons are 
enabled.

IMPORT / EXPORT

Export:

Press the [Events] button and all programmed events are stored with the file name of “EVENTS.CFG”.

Press the [Config] button and the controller configuration and holidays are saved with the file name of 
“CONFIG.CFG”

Import:

Press the [Events] button and the controller looks for the file named “EVENTS.CFG” and reads the events 
from it. Note: All current events are deleted before importing.

Press the [Config] button and the controller looks for a file named “CONFIG.CFG” and reads the 
configuration and holiday data.

Removing the USB drive will exit this window and return to the main menu window. If you use the red X 
button to exit this window be sure to remove your USB drive.

Summary of Contents for 5400-E

Page 1: ...luding court costs and attorney fees being assessed against the party misusing this property Artisan Controls Corporation 111 Canfield Ave Bldg B15 18 Randolph NJ 07869 www artisancontrols com 5400 E...

Page 2: ...splay and includes two relay contact outputs two DC outputs for driving solid state relays two switch inputs and a USB port for importing and exporting the controller configurations MAIN SCREEN The ma...

Page 3: ...touch the item and it toggles back and forth Output Buttons Touching any of the output buttons displays the events in its schedule this event occurs at 7 00 am the output is turned ON and this happen...

Page 4: ...nts Page 4 V1 05 MAIN MENU If password security has been enabled the access code entry window below will appear requesting the 4 digit code This screen will show the digits as asterisks for security P...

Page 5: ...with on your 4950 This one controller can perform all the function of the 4950B bell controller 4950H event controller and all controllers derived from those products SCHEDULES Important Features 1 An...

Page 6: ...f Contents Page 6 V1 05 SCHEDULE EDITING Once you select the output to edit its schedule is displayed in the window to the right All the events are sorted and shown in sequence the up and down arrows...

Page 7: ...ed ON Output turns ON when the event is activated OFF Output turns OFF when the event is activated Event Duration The event duration determines how long the output stays in that state 1 An event durat...

Page 8: ...e you want to copy from and it turns green if it has a schedule Then press the output button you want to copy the schedule to and it highlights If the from output has events and there are enough event...

Page 9: ...0 E controller allows you to enter up to 15 holidays On a holiday all output schedules are disabled and the outputs will be turned off from midnight to midnight Press the Holidays button and the windo...

Page 10: ...to change it from ON to OFF and vice versa Pressing the Edit button opens the access code window to change the current access code Enter the four digits you want and then press ENTER The Clear button...

Page 11: ...ress the USB button in the main menu and this window appears NOTE Do not insert the USB drive until you are in this window Once you insert the USB drive the controller indicates that it has detected i...

Page 12: ...the main menu allows the user to check the proper functioning of the controller outputs and inputs and also allows clearing the entire controller configuration back to the factory defaults You must p...

Page 13: ...uplication misuse or conversion of this information without theexpress written consent of Artisan Controls Corporation is illegaland will result in damages including court costs and attorney fees bein...

Page 14: ...onsent of Artisan Controls Corporation is illegaland will result in damages including court costs and attorney fees being assessed against the party misusing this property Artisan Controls Corporation...

Page 15: ...t inputs 5mA 5VDC OUTPUTS OUT1 OUT2 SPNO relay contacts rated 10A 125V 7A 250V OUT3 OUT4 5VDC 50mA maximum2 FUNCTIONALITY Up to 128 events usable for any output configurable for any number of days of...