ARTEX AIRCRAFT SUPPLIES
Document # 570-2225
6.5.2
If a printer is not connected to the selected printer port, the software may lock up. If it will
not respond hit Ctrl-Alt-Del together. This will bring up a Windows task list. You should
see the software routine (called Artex ELT Programmer) on the list. Select it and chose
“End Task”. If prompted, chose “End Task” again. If this does not close the program
down, wait and then follow this sequence again.
6.5.3
After printing the ELT programming data, include the printout with a copy of the
“ARTEX 406 MHz PROGRAMMING RECORD” for this ELT. This form can be found
at the end of this manual. Details for its use will follow. Mark the box indicating that a
printout is attached to the programming record.
6.6 Software Exit
6.6.1
Select “EXIT” from the “FILE” menu or press and release “ALT” then “F” then “X” on
the keyboard.
6.6.2
Turn the level shifter off and disconnect it from the ELT.
7 Programming the C406-N series PA (Programming Adapter)
The C406-N series ELT’s offer an accessory programming adapter designed to reprogram
the attached ELT to match the programming contained within the programming adapter.
This feature is used by fleet operators to facilitate ELT exchange for maintenance purposes.
The C406-N series PA is programmed in exactly the same manner as an ELT, as described
in the section above.
A C406-N series ELT intended for use with the PA is typically shipped with generic Serial
User – Aviation/ELT Cospas (Short) programming as described in the ELT programming
section above and will be overwritten by the PA.
Page
16
7.1 Hardware Operation
Communication between the PA and the host computer using the 500-0232 level shifter and
510-0406 programming software requires translation by a C406-N series ELT or PA-PI. To
program a PA, attach it to the level shifter’s male 22-pin circular connector. Attach a C406-
N series ELT or PA-PI to the 22-pin female circular connector.
WITH CANNON PLUG ATTACHED TO PA:
Communication between the PA and the level shifter requires translation by a C406-N series
ELT or a Programmable Adapter – Programmer Interface (PAPI), P/N 500-8000.
Program a PA by attaching it to the level shifter using the cable P/N 611-0111. The male 22-
pin circular connector attaches to the PA and the cable 22-pin female circular connector
attaches to a C406-N series ELT or PA-PI.