background image

20

EN

Hy

draulic

 s

che

me

Stand

-b

y

Stand-by 

state

Season

circu

la

to

r h

ea

ter

 

co

n

dition

State h

eat

in

g h

ydr

o in

sert

HEA

TING +

 AC

S IN CONT

AC

T

SAN

IT

A

RY

 DOE

S NOT

 C

ALL

OFF

01 (A

MB.)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

M

O

D

U

LE

 IF

 P

RO

BE

 H

2

O>

 S

ET

 H

2

(a

); 

IF

 A

M

PR

O

BE

 >

 A

IR

 S

ET

 (b

)

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 IN

 C

ALL

OFF

01 (A

MB.)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

H

2

O

 >

 A

CS

M

O

D

U

LE

 IF

 PRO

BE

 H

2

O>

 80 °

 C

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 DOE

S NOT

 C

ALL

ON

01 (A

MB.)

WINT

ER

ON

 IF

 H

2

O

 >

 PR. 25

MO

D

ULE

 S

H2O>

 SET H

2

O;

 (a) ST

AND-

BY IF

 AMB PRO

BE.

 >

 SET

 AMB .; (B

)

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 IN C

A

LL

ON

01

 (AMB.)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

H

2

O

 >

 A

CS

MO

D

ULE IF

 P

ROBE

 H

2

O>

 80 °

 C

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 DOE

S NOT

 C

ALL

OFF

02 (

H

2

O

)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

MO

D

ULE

 IF

 PR

OBE

 H

2

>

 S

ET 

H2O (a)

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 IN

 C

ALL

OFF

02 (

H

2

O

)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

H

2

O

 >

 A

CS

M

O

D

U

LE

 IF

 PRO

BE

 H

2

>

 80°

C

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 DOE

S NOT

 C

ALL

ON

02 (

H

2

O

)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

ST

AND-

BY

 IF PROBE

 H

2

>

 S

ET 

H2O (a)

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 IN

 C

ALL

ON

02 (

H

2

O

)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

H

2

O

 >

 A

CS

M

O

D

U

LE

 IF

 PRO

BE

 H

2

>

 80°

C

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 DOE

S NOT

 C

ALL

OFF

03 (TERM. ES.)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

M

O

D

U

LE

 IF

 E

XT

ER

N

A

TH

ER

M

O

ST

AT 

SA

TI

SF

IE

D

 O

IF 

PR

O

BE

 H

2

O>

 S

ET

 H

2O

 (a

)

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 IN

 C

ALL

OFF

03 (TERM. ES.)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

H

2

O

 >

 A

CS

M

O

D

U

LE

 IF

 PRO

BE

 H

2

>

 80°

C

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 DOE

S NOT

 C

ALL

ON

03 (TERM. ES.)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

ST

AND-

BY

 EXTERNAL TH

ER

MOST

AT

 

SA

TISFI

ED;

MO

D

ULE

 IF

 H

2

O>

 S

ET H

2

O;

 (t

o)

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 IN

 C

ALL

ON

03 (TERM. ES.)

WINTER

ON

 IF

 H

2

O

 >

 PR. 25

H

2

O

 >

 A

CS

M

O

D

U

LE

 IF

 PRO

BE

 H

2

>

 80°

C

HEA

TING +

 AC

S IN

 C

ONT

A

CT

SAN

IT

A

RY

 DOE

S NOT

 C

ALL

OFF

/ON

01/02/

03

SUMMER

ON

 IF

 H

2

O

 >

 PR. 25

ST

AND-

BY

HEA

TING +

 AC

S IN CONT

AC

T

SAN

IT

A

RY

 IN

 C

ALL

OFF

/ON

01/02/

03

SUMMER

ON

 IF

 H

2

O

 >

 PR. 25

H

2

O

 >

 A

CS

M

O

D

U

LE

 IF

 PRO

BE

 H

2

>

 80°

C

Summary of Contents for Hydro Insert 17

Page 1: ...t will be installed The wall where the product will be placed must not be constructed in wood or in any case made of an in ammable material and in addition it is necessary to maintain a safety distanc...

Page 2: ...all into the collection compartment Nevertheless check the basket daily given that not all pellets have high quality standards use only quality pellets recommended by the manufacturer Responsibility W...

Page 3: ...ass handle and tubes become very hot during operation do not touch these parts without adequate protection Keep the fuel and other in ammable materials off the Hydro Insert Charge pellet Fuel is loade...

Page 4: ...dro Insert is in operation The Hydro Insert must be connected to an electrical system equipped with an earthing conductor in accordance with regulations 73 23 and 93 98 EEC The system must be of adequ...

Page 5: ...B 1 Measures with a tolerance of about 10 mm 2 Measures and images are indicative and can vary depending on the aesthetic of the pellet Hydro Insert Technical Speci cation Hydro Insert 17 25 420 C B A...

Page 6: ...6 1 69 5 25 Heated surface mc 300 450 Flue gas ow rate min max g s 5 49 10 80 5 85 13 58 Draft min max Pa 3 10 3 12 Flue gas temperature min max C 68 8 115 1 82 3 160 6 Hydro Insert water litri 30 30...

Page 7: ...the Hydro Insert is to be installed must be strong enough to take its weight Keep a minimum distance of 50 mm between the covering and the replace insert If walls are ammable maintain a minimum dista...

Page 8: ...less steel pipe must not be used At the bottom of the ue pipe provide an inspection cap to allow periodic checking and cleaning which must be done annually Make a gas tight connection to the ue pipe u...

Page 9: ...y cap must be a wind proof type and must be above the ridge Eventual structures or other obstacles that are higher than the chimney cap must not be too close to the chimney cap itself The device shoul...

Page 10: ...sert pedestal rst you have to x it to the oor and choose the height of the legs If you install the lateral load it is advisable to keep the minimum size so as not to have the loading entrance too high...

Page 11: ...d the lever on the side of the same replace the battery observing the correct polarity Fig 4 Fig 3 Fig 4 It is mandatory to have an opening in the brick plasterboard coating to guarantee an adequate s...

Page 12: ...larm sounds temperature Indicator pressure indicator audio alarm automatic adjustment safety thermostat with manual reset circulation system Directions for use If the installation of the Hydro Insert...

Page 13: ...f water in the system of recirculation must be stable hold Experiences show that the user must regularly check the water level every 14 days in order to maintain a stable water content The replenishme...

Page 14: ...tions drastically reduce performance because of their low thermal conductivity freshwater 0 12 water medium 12 20 hard water 20 30 very hard water over 30 The pellets are cylinders of compressed wood...

Page 15: ...lect the required hydraulic scheme number For end user It is possible to change the Hydro Insert operating principle according to the season by choosing between summer and winter To select the season...

Page 16: ...D TECHNICIAN How to select the type of Stand by OPERATION BY A SPECIALIZED TECHNICIAN Press the SET button press button to go to menu 09 Press the SET button again Enter the access key and con rm it b...

Page 17: ...n the room using the probe on the board press the key Increase or decrease degrees with the and keys c To set the work power press the key and adjust it with the e Reaction from the stand by state is...

Page 18: ...02 H 2 O WINTER ON IF H 2 O PR 25 MODULE IF PROBE H 2 O 80 C HEATING SANITARY SANITARY DOES NOT CALL OFF 03 TERM ES WINTER ON IF H 2 O PR 25 MODULE SE TERM ES SATISFIED OR IF H 2 O PROBE SET H 2 O a...

Page 19: ...ealth risk I Valve motorization II External thermostat ON OFF or stand by type 3 optional III ON OFF thermostat on ACS tank Scheme 01 the hydro insert is connected to a domestic hot water tank and to...

Page 20: ...MODULE IF PROBE H 2 O 80 C HEATING ACS IN CONTACT SANITARY DOES NOT CALL ON 02 H 2 O WINTER ON IF H 2 O PR 25 STAND BY IF PROBE H 2 O SET H2O a HEATING ACS IN CONTACT SANITARY IN CALL ON 02 H 2 O WIN...

Page 21: ...desired temperature in the room using the probe on the board press the key Increase or decrease degrees with the and keys The working power is automatically set from the machine The rinsing from the...

Page 22: ...2 O PR 25 WORK AND IF H 2 O PROBE 80 MODULE CONTACT PUFFER LOW THERMOSTAT DOES NOT CALL AND HIGH CALL OFF 01 02 03 WINTER SUMMER ON IF H 2 O PR 25 WORK AND IF H 2 O PROBE 80 MODULE CONTACT PUFFER LOW...

Page 23: ...decrease degrees with the and keys c To set the work power press the key and adjust it with the and keys d To adjust the temperature inside the DHW tank press the button Increase or decrease the desi...

Page 24: ...25 STAND BY IF PROBE H 2 O SET H 2 O a HEATING DHW WITH PROBE PROBE ACS SET ACS ON 02 H 2 O WINTER ON IF H 2 O ACS 3 AND IF H 2 O PR 25 RATED HEAT INPUT IF PROBE H 2 O SET ACS 10 d HEATING DHW WITH PR...

Page 25: ...ress the key Use the and keys to select the desired degrees b To set the temperature on the bottom of the puffer press the key and use the e and B keys to select the desired degrees The working power...

Page 26: ...H 2 O S1 3 H 2 O PR 25 H 2 O PROBE 80 RATED HEAT INPUT 2 SIDE PUFFER 4 S1 E S2 SET PUFFER ON 01 02 03 WINTER SUMMER OFF OFF STAND BY 2 SIDE PUFFER 4 S1 E S2 SET PUFFER ON 01 02 03 INVERNO ESTATE ON O...

Page 27: ...the relays are not controlled by the hydro insert control unit a To set the temperature in the DHW tank press the key Use the and keys to select the desired degrees b To set the temperature in the tec...

Page 28: ...01 02 03 WINTER ON IF H 2 O PROBE PUF FER 3 H 2 O PR 25 OPERATION AND RATED HEAT INPUT H 2 O PROBE 80 PUFFER DHW TANK WITH PROBE DHW PROBE DHW SET AND PUFFER PROBE SET PUFFER OFF 01 02 03 WINTER ON IF...

Page 29: ...I EN ISO 17225 2 standard Keep the pellets away from heat sources and not in humid environments or with explosive atmosphere Control Panel Button is used to switch the machine on off and to exit progr...

Page 30: ...achine starts loading the pellets into the brazier The fume extractor and the cochlea engine are active BRAZIER CLEANING The machine is cleaning the basket The smoke extractor runs at maximum speed an...

Page 31: ...Once the thermostat is activated deactivated press button 4 OFF and continue scrolling though the submenus using button 5 Select which submenu you wish to enter in order to access the daily weekly and...

Page 32: ...9 saturday prog 1 on off 10 sunday prog 1 on off 11 start program 2 hour 12 stop program 2 hour 13 monday progr 2 on off 14 tuesday progr 2 on off 15 wednesday prog 2 on off 16 thursday prog 2 on off...

Page 33: ...sable and set the weekly functions of the thermostat It s possible to set more operating ranges delimited by the times set according to the following table where the OFF setting tells the clock to ign...

Page 34: ...3 08 FRIDAY PROGRAM 1 on off 02 03 09 SATURDAY PROGR 1 on off 02 03 10 SUNDAY PROGR 1 on off PROGRAMME 3 menu level selection meaning possible values 03 03 20 START PROGRAM 3 activation time time OFF...

Page 35: ...Center ALAR 5 NO LIGHTIN The Hydro Insert cannot start up This is the rst light up Fill in the tank with pellets Start up again ALAR 6 NO PELLET The pellet Hydro Insert switched off while working Fill...

Page 36: ...r ends You will then read the words KL MB B on the display and the stove switches off Press the key On Off to reset the alarm Wait until the cooling phase is completed Clean the brazier and start a ne...

Page 37: ...o Insert Other fuses to protect the electronic boards are to be found on the boards themselves Reduction motor if the motor stops the Hydro Insert continues to function until the ame goes out for lack...

Page 38: ...ash Internal parts Flue pipe Circulation pump Hydraulic components Electromechanical components The Hydro Insert requires a simple and thorough cleaning in order to ensure a more ef cient performance...

Page 39: ...use abrasive or aggressive products or materials Clean with damp cotton or paper towels The silicon paints used by manufacturer possess technical characteristics that make them resistent Shutting the...

Page 40: ...15 AT delayed type Plug the unit back in and press the main switch Exchanger cleaning Remove the combustion chamber plate to remove it push the plate upwards and then rotate it towards the front CLEA...

Page 41: ...criminal liability Use only original spare parts Replace a worn before failure promotes the prevention of injuries resulting from accidents caused by the sudden failure of the components After 1300 ho...

Page 42: ...acement of parts with other non original The operations marked in bold type must be carried out by specialised personnel Problems and solutions PROBLEM POSSIBLE CAUSE REMEDY Pellet not being fed into...

Page 43: ...place the pressure The Hydro Insert runs for a few minutes and then goes out 1 Lighting cycle not completed 2 Temporary failure of electricity supply 3 Smoke duct obstructed 4 Temperature sensors defe...

Page 44: ...r in them 1 Free up the circulator by removing the plug and turning the shaft with a screwdriver Check the electrical connections of the same replace if necessary 2 Vent the radiators Hot water in not...

Page 45: ...rt or for causes not attributable to the manufacturer for incorrect installation for incorrect electrical connection for periodic maintenance not performed for outdoor accidents lightning oods etc for...

Page 46: ...46 EN NOTES Cod 001111...

Reviews: