43
EN
The re goes out or
the Hydro Insert stops
automatically
1. Pellet hopper empty
2. Pellets not being fed in
3. Intervention of pellet
temperature sensor
4. Door not closed properly or
gaskets worn
5. Hydro Insert temperature is too
high
6. Unsuitable pellets
7. Low pellet feed rate
8. Combustion chamber dirty
9. Smoke outlet obstructed
10. Smoke extraction motor failed
11 Pressure switch faulty or
defective
1. Re ll pellet hopper
If it is rst ignition the fuel, having to go the route that
goes from the tank to the brazier, may not be able to
arrive on time and in the right amount programmed
2. If after repeated ignitions did not appear in the
ame, even with regular supply of pellets, the
problem may be related to the components of the
heater or the improper installation
3. Let the Hydro Insert cool down completely, reset the
thermostat till lockout ceases, relight Hydro Insert;
if problem persists, contact technical assistance
4. Close the door or
replace the gaskets with
original spare parts
5. Check for proper operation of the water pump,
if necessary, replace the component
6. Change to a type of pellet recommended by the
manufacturer
7. Have the fuel feed rate checked by technical
service
8. Clean the combustion chamber, following
instructions in the manual
9. Clean the smoke duct
10. Check the motor and replace if necessary
11. Replace the pressure
The Hydro Insert runs
for a few minutes and
then goes out.
1. Lighting cycle not completed
2. Temporary failure of electricity
supply.
3. Smoke duct obstructed.
4. Temperature sensors defective
or broken.
5. Sparkplug failure.
1. Re-run lighting cycle
2. See previous instruction
3. Clean smoke duct
4. Check and replace sensors as necessary
5. Check the plug and replace if necessary
Pellet build up in grate,
door glass gets dirty
and ame is weak
1. Insuf cient combustion air
2. Pellets damp or unsuitable
3. Smoke extractor motor broken
4. Bad adjustment. Wrong ratio
between air and pellet
1. Check that the room air intake is present and free.
Check that the pipe Ø 5 cm for air inlet is not obstructed.
Clean the grate and check that all the airways are clear.
Carry out a general cleaning of the combustion
chamber and the smoke duct.
Check the state of the door gaskets
2. Change the type of pellet
3. Check the motor and replace if necessary
4. Contact your Authorized Assistance Center
The smoke extraction
motor does not work
1. No electrical supply to
the Hydro Insert
2. The motor is broken
3. Defective electronic board
4. Control panel broken
1. Check the supplay voltage and the protection fuse
2. Check the motor and capacitor and replace
if necessary
3. Replace electronic board
4. Replace the control panel
The air fan convention
never stops
1. Temperature sensor temperature
control defective
or broken
2. Fan failure
1. Check operation of the sensor and replace
if necessary
2. Check operation of the motor and replace
if necessary
Summary of Contents for Hydro Insert 17
Page 46: ...46 EN NOTES Cod 001111...