DLC300 Function Module Installation and Operations Manual
DLC300 Function Module
5. Install the SFPs into the DLC300 (handle on top as shown in
Figure 5
). Push each SFP into the sockets
located on the right side of the function module until they are firmly seated into the socket. If you are
installing only one SFP, you can install it in either the primary (PRI) or secondary (SEC) SFP socket.
Note:
When you do not install any SFP, both sets of TX and RX status LEDs located on the DLC300
front panel flash. See
Table 6
for other status LED indications.
6. Repeat this procedure for each DLC300 that you are installing in the chassis.
Figure 5.
DCL300 Module and SFP Installation
Note:
Insert a blank tray in any unused chassis module slots to maintain proper ventilation.
Cabling the DLC300 Module
The DLC300 allows you to transmit and receive signals over electrical and fiber optic cable connections. The
cabling configuration that you use depends on your application. The electrical and optical connectors are
located on the back panel of the DLC300 (see
Figure 6
). You access the connectors from the rear panel of the
chassis.
Figure 6.
DLC300 BNC Electrical and SFP Optical Connectors
Note:
When handling fiber optic cables, adhere to the standard safety practices for handling a Class 1
laser product (see the
“DLC300 Laser Warnings” section on page 2
).