![Artel DigiLink DLC300 Installation And Operation Manual Download Page 19](http://html1.mh-extra.com/html/artel/digilink-dlc300/digilink-dlc300_installation-and-operation-manual_2977520019.webp)
DLC300 Function Module Installation and Operations Manual
9
Configuring the DLC300 Module Operation
Setting the SW4 Mode Select Switch
The SW4 mode select switch (see
Figure 3)
determines the operating mode for your DLC300.
Figure 3.
DLC300 SW4 Mode Select Switch
Table 2
describes the operating mode options and the signal types that are present depending on the
operating mode.
Table 2.
SW4 Mode Select Switch
Mode
I/O
Transmit (TX)
Receive (RX)
Repeat (RPT)
Electrical In
BNC IN or backplane from
another module (user selected).
Not used.
Not used.
Optical In
Not used.
Primary or secondary
SFP (automatically
selected).
Primary or secondary
SFP (automatically
selected).
Electrical Out
BNC OUT
Same as Electrical In.
Same as Optical In.
1
Same as Optical In.
1
Backplane to
other modules
Same as Electrical In.
1
Same as Optical In.
1
Same as Optical In.
1
Monitor
Same as Electrical In.
2
Same as Optical In.
1
Same as Optical In.
1
Optical Out
Same as Electrical In.
1
Not used.
Same as Optical In.
1. Subject to EG-34 dithering as configured by the EG-34 dithering DIP switch (see
“Setting the SW3 Configuration
DIP Switch” section on page 11
).
2. When ATSC-to-ASI conversion is enabled, the monitor output is the ASI version of the signal (see
“Setting the SW3
Configuration DIP Switch” section on page 11
).
Setting the Configuration DIP Switches
The SW1, SW2, and SW3 configuration DIP switches (see
Figure 4
) determine the functionality of the DLC300
as follows:
•
SW1—Controls the video rate and forced bypass function settings.
•
SW2—Controls the input source (BNC IN or backplane connector) for transmitter mode and
operation of the standby video pattern generator.
•
SW3—Controls the following functions: SDI dithering, ATSC to ASI video conversion, SFP alarms,
optical reversion, video loss alarm, and EMS enable setting.