background image

Page 14

Scan Do® HD User’s Manual 

Scan Do® HD 

Warranty

Artel Video Systems (Artel) warrants that, for a period of three years after purchase 

by the Buyer, this product will be free from defects in material and workmanship 

under normal use and service.  A Return Material Authorization (RMA) number 

must be obtained from Artel before any equipment is returned by the Buyer. All 

materials must be shipped to Artel at the expense and risk of the Buyer.

Artel’s obligation under this warranty will be limited, at its option, to either the 

repair or replacement of defective units, including free materials and labor.  In no 

event shall Artel be responsible for any incidental or consequential damages or 

loss of profits or goodwill.

Artel shall not be obligated to replace or repair equipment that has been dam-

aged by fire, war, acts of God, or similar causes, or equipment that has been 

serviced by unauthorized personnel, altered, improperly installed, or abused.

RMA numbers and repairs can be obtained from:

 

 

Artel Video Systems

 

5B Lyberty Way

 

Westford, Massachusetts 01886  USA

 

Tel:   (978) 263-5775

 

Fax:   (978) 263-9577

RMA numbers can also be obtained from our web site: 

artel.com

Please have your serial number available.

Summary of Contents for 1298

Page 1: ...h resolution DVI and analog RGB computer sources into a SMPTE standard 3G HD or SD SDI signal for broadcasting on air or integrating into a professional video production system Scan Do HD does not req...

Page 2: ...k Phasing 8 Anti Flicker Function 9 Test Signals 9 Restoring to Factory Default Settings 9 Locking the Front Panel 9 Fiber Optic Output On Off 9 On Screen Display OSD On Off 10 Capturing Storing EDID...

Page 3: ...ol Manual 1 Scan Do HD Front Panel Quick Reference Chart 1 Rack Mounting Kit 1 Accessory Pack Replacement fuse rubber feet Available Optional Accessories Fiber Matrix Optical Router for 3G HD SD signa...

Page 4: ...uct make sure that the product is properly grounded Prevent Electrical Circuit Overloading The unit operates from a single phase power source with the neutral conductor at or near earth ground The lin...

Page 5: ...utputs is determined by the settings for Line Count Vert Rate I P and Rate Div Note If one of the 3G HD SD SDI Outputs is not used it should be terminated at the connector in 75 ohms to improve the ey...

Page 6: ...tton Available resolutions will illuminate in the Line Count row The flashing LED indicates your selection Use the LEFT and RIGHT Arrow keys to change your desired Line Count Step 2 After making your...

Page 7: ...oom Genlock Phasing IP Address F3 Decrease Increase Delay Advance Capture EDID Cancel Fiber Reset Ethernet Processing Control Output Format Pan Zoom IP Address Decrease Increase Delay Advance Capture...

Page 8: ...offset NOTE For NTSC and PAL output formats set the Vertical Phasing to Zero Offset before adjusting any phasing NOTE Clock Phasing movement is in 840 picosecond pS increments and may not be visible o...

Page 9: ...crease Delay Advance Capture EDID Cancel Keypanel Fiber Reset Ethernet OSD Factory Defaults Alternate Function Genlock Anti flicker Processing Control Output Format Pan Zoom Genlock Phasing Recall Tes...

Page 10: ...tton Operation Turn On Off then On Off Button Operation Turn On Off then Capture Store then Enter Preset Store Mode Enter Preset Recall Mode Change Preset Position Execute Preset Store Execute Preset...

Page 11: ...that your browser have Java version 1 6 JRE 6 or later installed This is normally standard on most browsers However the latest version of Java can be downloaded at java sun com RS 232 This port is des...

Page 12: ...t of the PC Press the TEST button to see if you get color bars on the SDI outputs If you do get color bars then the problem is related to your input signal Check the items mentioned in the above bulle...

Page 13: ...features a re clocked and equalized SDI loop through and the 3351 receiver features two re clocked and equalized SDI outputs The 3350 Series is compliant with SMPTE 297 2006 and has the ability to op...

Page 14: ...at its option to either the repair or replacement of defective units including free materials and labor In no event shall Artel be responsible for any incidental or consequential damages or loss of pr...

Page 15: ...G TO REDUCE THE RISK OF FIRE OR ELECTRONIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRONIC SHOCK DO NOT REMOV...

Page 16: ...digital NTSC PAL black burst or HD tri level sync 3G HD resolutions will genlock to NTSC PAL black burst at the same vertical rate Passive loop through H V and Clock phasing with a range of one output...

Page 17: ...Page 17 Scan Do HD User s Manual Scan Do HD About Your Scan Do HD Serial Number Date of Purchase Purchased From Installed By Installation Location Configuration...

Page 18: ...Page 18 Scan Do HD User s Manual Scan Do HD Notes...

Page 19: ...Alternate Function Genlock Anti flicker Processing Control Output Format Pan Zoom Genlock Phasing Recall Test Preset Select Store IP Address F3 F2 F1 Decrease Increase Delay Advance Capture EDID Cance...

Page 20: ...ned exclusively for the A V Professional each Fiberlink is designed and built with decades of Pro A V experience Call your Sales Representative or visit us online at artel com Black White Blue World H...

Reviews: