DMX protocol
47
Mode 15: HSI, Coarse / fine channel per function
Overview of typical CCT values as DMX values
To calculate CCT values in DMX % and vice versa
Use the following formulas to transform CCT values in DMX %
values and vice versa:
CCT values for the ARRI L5 models:
L5-TT (Tungsten Tuneable)
CCT
min
= 2.600 K
CCT
max
= 3.600 K
L5-DT (Daylight Tuneable)
CCT
min
= 5.000 K
CCT
max
= 6.500 K
L5-C
CCT
min
= 2.800 K
CCT
max
= 10.000 K
Channel
Value
Percent
Function
1
0-255
0-100
Dimmer coarse
closed
→
open
2
0-255
0-100
Dimmer fine
3
0-255
0-100
Hue coarse
0
→
360°
4
0-255
0-100
Hue fine
5
0-255
0-100
Saturation coarse
0
→
full saturated
6
0-255
0-100
Saturation fine
CCT-
Value
DMX-Value (8 bit)
DMX-Value (16 bit)
L5-TT
L5-DT
L5-C
L5-TT
L5-DT
L5-C
3.200 K
153
--
14
39.321
--
3.670
5.600 K
--
102
99
--
26.214
25.493
6.000 K
--
170
113
--
43.712
29.098
6.500 K
--
100%
131
--
65.535
33.685
CCT
Target
CCT
max
CCT
min
–
(
)
DMX
in percent
×
100
-----------------------------------------------------------------------------------------
CCT
min
×
=
DMX
in percent
CCT
recent
CCT
min
–
CCT
max
CCT
min
–
------------------------------------------------- 100
×
=
Summary of Contents for L5