17
8
Check if the camera:
• stops at the selected point
• whether the camera exceeds the point
• whether the camera is bouncing left and right
9
If the camera exceeds the desired point,
increase
the
P
and
D values
in increments of five.
NOTE
The
D value
must be min. 5 steps
higher
then the
P value.
NOTE
When the remote head starts to
vibrate
,
reduce
the
P value
!
10
If the remote head
bounces
to the left and
right when you reach the desired point, you
must slowly
increase
the
D value
of the
Pan
axis.
11
Once the
PID
value of the Pan axis meets
your expectations, the same
PID
value will
be used for the
Tilt
axis as well.
Press
Save!
Step 14
12
Drop
At very steep angles, the weight distribution
of the camera setup changes extremely.
The Drop setting permanently balances the
Pan and Tilt values as the camera angle
gets steeper and steeper.
Slowly move the camera to the 90° top-down
position.
As the remote head begins to
vibrate
, slowly
increase
the
Drop
value until the remote head
stops vibrating
.
NOTE
Without
any
Drop
compensation,
strong vibrations
occur
at steep angles.
NOTICE
It is important to
understand
and to
accept
that all necessary steps, such as
setting up the camera, attaching the remote head to the crane, the quality of the
crane itself and the PID settings, must be taken into account and properly
performed. If only one step is missing, the desired overall system performance
can not be achieved.
PID / Quick Setup