Motor preparation
15
Setting up motor
1. Connect the motor to its control device.
2. Use the SETUP button to assign the cforce motor to the focus,
iris or zoom control of the control device. Make sure that the
assignment matches the lens scale the motor is attached to.
3. Set the motor side/direction on the control device.
4. Set the motor torque on the control device.
5. Press the SETUP button for three seconds to start the
automatic calibration of the respective motor. Alternatively,
activate the calibration process though the control device.
CAUTION!
Risk of injury!
Do not touch motor gear while motor is powered
up!
NOTICE
To prevent the motor from falling down when detaching the
motor from the lens, hold the motor unit with one hand while
opening the clamp console.