5.15. CLM-2 Cable Swap
The regular cables of the CLM-2s should be exchanged for the longer cables CC-M2.
• Remove the seven straight slotted screws that hold the cover, then remove the cover.
Screws
Screws
• Use a screwdriver with a thin blade to carefully remove the cable connector from the CLM-2.
Cable Connector
• Lift the cable out of the CLM-2 motor. Remove the silver strain relief from the cable.
Strain Relief
• Flip the motor over and loosen the strain relief screw with a 2 mm hex driver.
Strain Relief Screw