![Armstrong HumidiClean HC-4100 Series Installation, Operation And Maintenance Instructions Download Page 28](http://html1.mh-extra.com/html/armstrong/humidiclean-hc-4100-series/humidiclean-hc-4100-series_installation-operation-and-maintenance-instructions_2974159028.webp)
28
HC-4500 Repair Parts
Item
No. Heating
Element
w/TC
Tap
Water
Part
No.
40a
6.65KW
240vac
B5434-1
40b
8KW
220vac
B5438-1
40c
8KW
277vac
(480vac)
B5438-2
40d
8KW
346vac
(600vac)
B5438-3
Item
No.
Heating
Element
w/TC
DI/RO
Part
No.
40e
6.65KW
240vac
B5436-1
40f
8KW
220vac
B5440-1
40g
8KW
277vac
(480vac)
B5440-2
40h
8KW
346vac
(600vac)
B5440-3
Item
No.
Miscellaneous
Part
No.
a
Hardware
Kit
(not
shown)
A21912
b
Hose
Cuff
(not
shown)
B2851A
c
Insulation
Kit
(not
shown)
D3351
Component
Voltage
Resistance
Fill Valve
24 vac
8.8
Ω
Drain Valve
24 vac
4.1
Ω
Thermocouple in Heating
Element
—
0.51
Ω
208, 240, 380 Volt
30/33.5/40/45/50.3/60 kW
240 V
7.4 - 9.1
Ω
380 Volt 72 kW
220 V
5.2 - 6.3
Ω
480 Volt 72 kW
277 V
8.1 - 10.0
Ω
600 Volt 48/72 kW
346 V
12.8 - 15.7
Ω
208 vac 18
Ω
across H1-H2
240 vac 21
Ω
across H1-H3
277 vac 24
Ω
across H1-H4
380 vac 40
Ω
across H1-H5
480 vac 53
Ω
across H1-H6
600 vac 97
Ω
across H1-H2
208 vac
1
Ω
across X1-X2
240 vac
1
Ω
across X1-X2
277 vac
1
Ω
across X1-X2
380 vac
1
Ω
across X1-X2
480 vac
1
Ω
across X1-X2
600 vac
1
Ω
across X1-X4
Power Transformer
Primary Winding
Secondary Wiring
Resistance Values of Components
Heating Elements