e)
Allow the unit to run for at least one hour.
f)
Power the unit down at breaker.
g)
Set the dip switches to the desired settings. See Page 22 for the dip switch
settings.
h)
Power the unit up at breaker.
End of Season Drain
If at any time during normal operation there is not a demand for a continuous 72 hour period,
HumidiClean drains the tank and the PC Board initiates a drying cycle by cycling the heating
elements for short intervals in order to dry the ionic beds.
Maintenance
The HumidiClean is designed to minimize maintenance. As stated in the PRINCIPLE OF
OPERATION section, after the HumidiClean has accumulated 90% of the selected Service Life, in
hours of heater on time, the “SERVICE LIFE” LED will flash (blink). At this time the ionic beds in the
tank should be replaced. If service is not performed, the unit will continue to operate for the
remaining hours before shutting down completely.
Note: Service Life can be adjusted based on water quality. If Ionic Beds are relatively free of scale
deposits or scale is forming on tank walls and elements because beds are saturated with scale,
Please consult the factory for Service Life adjustment procedures.