1.1 

Pictographs Used

In this manual, pictographs are used as hazard warnings.

Particular information, instructions and restrictions 
designed for the prevention of personal or substantial 
property damage:

 WARNING! Is used to warn you against an 

imminent danger that may result in personal 
injury or death.

  

IMPORTANT! Is used to warn you against 
a possibly hazardous situation that may re-
sult in personal, property or environmental 
damage.

  

CAUTION! Is used to draw your attention to 
important recommendations to be observed. 
Disregarding them may result in property 
damage.

 Passages in the text containing 

explana-

tions, information or advice are highlight-
ed with this pictograph.

  The following symbol highlights 

actions you have to conduct 
or 
instructions that have to be strictly observed.

1.2 

Exclusion of Liability

We accept no liability for any damage or malfunction 
resulting from incorrect installation, inappropriate use 
of the device or failure to follow the instructions in this 
manual.

2. 

Safety Instructions

Please read this operating instruction thoroughly be-
fore operating the digital pressure gauge.
Disregarding the containing warnings, especially the 
safety instructions, may result in danger for people, 
the environment, and the device and the system it is 
connected to.
The digital pressure gauge corresponds with the state 
of engineering at the time of printing. This concerns 
the accuracy, the operating mode and the safe op-
eration of the device. In order to guarantee that the 
device operates safely, the operator must act compe-
tently and be conscious of safety issues.
The ARMANO Messtechnik GmbH provides support 
for the use of its products either personally or via rele-
vant literature. The customer verifies that our product 
is fit for purpose based on our technical information. 
The customer performs customer and application 
specific tests to ensure that the product is suitable 
for the intended use. With this verification, all hazards 
and risks are transferred to our customers. Our war-
ranty expires in case of inappropriate use.

 Qualified personnel:

•  The personnel that is charged for the installation, 

operation and maintenance of the instrument must 
hold a relevant qualification. This can be based on 
training or relevant tuition. The personnel must be 
aware of this manual and have access to it at all 
times.

•  The electrical connection shall be carried out by a 

fully qualified electrician only. 

Summary of Contents for DPG 2600

Page 1: ...tly at ARMANO Messtechnik GmbH Location Beierfeld Am Gewerbepark 9 08344 Gr nhain Beierfeld Tel 49 3774 58 0 Fax 49 3774 58 545 mail armano beierfeld com Location Wesel Manometerstra e 5 46487 Wesel G...

Page 2: ...oroughly be fore operating the digital pressure gauge Disregarding the containing warnings especially the safety instructions may result in danger for people the environment and the device and the sys...

Page 3: ...other wise any warranty and manufacturer responsibility expires In order to ensure measurement accuracy and du rability of the instrument and to avoid damage the limit values indicated in the technic...

Page 4: ...cker The nameplate is located on the device It contains the most important technical data and information Figure 1 nameplate Scope of delivery Digital pressure gauge DPG 2600 Calibration certificate O...

Page 5: ...be operated without batteries us ing only the mains adapter Four NiMH batteries size AAA are installed as standard power supply which can also be recharged via the mains adapter 6 Commissioning Befor...

Page 6: ...and off A flashing symbol is displayed on the screen during logging Up to 8 logs in CSV format can be downloaded via the RS 232 port optional RS 232 data cable and software BAUD RATE sets the baud ra...

Page 7: ...instrument in its original pack aging If possible remove the packaging not until installa tion of the device Store the instruments in a dry place not exposed to direct sunlight The storage temperatur...

Page 8: ...your supplier or to the ARMANO Messtechnik GmbH Disposal of used batteries Cover the poles with tape during storage and dis posal to avoid short circuits Dispose of used batteries properly in commerc...

Page 9: ...E 2014 30 EU OF THE EUROPEAN PARLIAMENT AND THE COUNCIL from February 26 2014 on the approximation of the laws of the Member States relating to the electromagnetic compatibility short EMC Directive DI...

Page 10: ...B78 01 22 GB p 10 of 12 www armano messtechnik com Operating Instructions Digital Pressure Gauge DPG 2600...

Page 11: ...www armano messtechnik com p 11 of 12 GB 01 22 B78 Operating Instructions Digital Pressure Gauge DPG 2600...

Page 12: ...changes replacement of materials and printing errors excepted ARMANO Messtechnik GmbH Location Beierfeld Am Gewerbepark 9 08344 Gr nhain Beierfeld Tel 49 3774 58 0 Fax 49 3774 58 545 mail armano beier...

Reviews: