Arktek YBC-10 User Manual Download Page 4

Device Features

MPPT (Maximum Power Point Tracking ) module supports a high utilization rate of solar 
energy.

High efficiency thermoelectric refrigeration system and heat pipe heat transfer system.

Advanced materials and superior vacuum insulation.

Maintain stable 2° to 8°C storage.

Maintain stable 2° to 8°C storage.

Keeps vaccines safely between 2° and 8°C for at least 3 days in a constant ambient
temperature of 43°C with no external power source. 

Real-time temperature display and 30 day temperature record.

Visual and audible alarm for out-of-range temperature.

Lid lock for secure storage.

Easy to use and maintain. (simple, safe, robust and reliable) 

Specifications

ITEM

SPEC

Model identifier

Alpha-numeric designation

YBC-10

Alpha-numeric designation

Ambient Temperature

Expected conditions of surrounding environment of use

5°C to 43°C

Vaccine storage temperature range

Internal temperature in vaccine payload area

2°C to 8°C

Capacity 

Volume of internal payload space

10 L

Unit Dimension (OD x H)

Outside diameter and height

φ528 x 860 mm

Cooling Type 

Type of the refrigeration

Thermoelectric

Voltage

Voltage

Voltage range during running

DC 16V to 24V

Solar array specification suggestion

Access electrical parameter for solar array 

Power: 200W
Imp: 10A

Net Weight 

Without packages

40 Kg

Gross Weight 

With packages

45 Kg

Delivery box dimensions (W x D x H)

As packaged for initial shipment from manufacturer

650 x 650 x 1000 mm

3

Summary of Contents for YBC-10

Page 1: ... service provider or visit the Website www aucmaglobal com cn and Email for info aucma com cn YBC 10 Solar Direct Drive Refrigerator User Manual Rev 202102 Caution Read this entire manual carefully before using the product Store this manual in a safe and accessible place for later reference as necessary ...

Page 2: ...tions 3 Safety Precautions 4 PARTS OVERVIEW 5 INSTALLATION 6 Preparation 6 Positioning the Device 6 USE OF THE YBC 10 7 Cool Down 7 Cool Down 7 Daily Use 7 Electronic System 11 MOVE AND TRANSPORT INSTRUCTIONS 14 CLEANING AND STORAGE 15 Cleaning 15 Condensate 16 TROUBLESHOOTING 17 DISPOSAL AND RECYCLE CONSIDERATION 18 WARRANTY 19 WARRANTY 19 1 ...

Page 3: ...th a thermoelectric refrigeration system TEC Thermal Energy Converter powered by a solar electric system with no battery The device uses technologically advanced materials with an extremely efficient vacuum device to isolate materials with an extremely efficient vacuum device to isolate the interior contents from external heat It includes a temperature record and alarm function that saves data fro...

Page 4: ...n simple safe robust and reliable Specifications ITEM SPEC Model identifier Alpha numeric designation YBC 10 Alpha numeric designation Ambient Temperature Expected conditions of surrounding environment of use 5 C to 43 C Vaccine storage temperature range Internal temperature in vaccine payload area 2 C to 8 C Capacity Volume of internal payload space 10 L Unit Dimension OD x H Outside diameter and...

Page 5: ...sons workers should turn off the power switch before starting scheduled maintenance work Do not place or operate the device near any flammable explosive corrosive materials any volatile gases liquids and any flammable gases Device is designed to store vaccine Do not use for other purposes e g do not use for storing liquid nitrogen Do not put anything in the device besides the approved ice packs va...

Page 6: ...PARTS OVERVIEW 5 ...

Page 7: ...in or around flammable or corrosive gases that could cause an explosion or electric shock an explosion or electric shock Place the device on a flat and solid ground and ensure the unit is level Locate and use the device in a dry well ventilated place Keep device away from direct sunlight and away from any other heat sources After loading the vaccine the device must remain upright In order to preve...

Page 8: ...s of consecutive solar cycles Step 4 In the case of intermittent solar power 4 hours of power each day and high ambient Step 4 In the case of intermittent solar power 4 hours of power each day and high ambient temperature environment the device may require 2 additional days after initial installation to reach full holdover capability Note In case of cloudy or rainy day the device may require more ...

Page 9: ...e of the other three square vaccine stacks into Insert Side Stacks 3 Place one of the other three square vaccine stacks into the center of the device Push the vaccine stack against one of the inside walls of the device 4 Repeat step 3 with another of the square vaccine stacks positioning it against the inside wall of the device opposite the vaccine stack This will leave a space in the center of th...

Page 10: ...s Set up vaccines daily or weekly There is a designated day use cup located in the top most accessible position in the device designed to hold all of the vaccine vials needed for the day The day use cup is designed to be easily accessible when the device is opened Figure 5 Loading cup stack cups with vaccines Day Use Cup to be easily accessible when the device is opened To administer the vaccines ...

Page 11: ... into place last so as to be located in line with the device access channel 8 Replace the cap on the device and latch the cap in place Place vaccines in day use cup Figure 6 Access vaccines Access vaccines for immunization session 1 Unlatch and remove the cap 2 Reach into the day use cup and take out vaccines Note Do not remove stacks during the day unless necessary to refill the day use container...

Page 12: ...veral choices for user to view the device s state and do other operations Use function keys to switch these interfaces Note for Function keys Press SET to start setting Press UP and DOWN to choose functions or add subtract Press UP and DOWN to choose functions or add subtract Press ENT to confirm continue or back exit General state Main interface Actual inner temperature TEC on off state and time ...

Page 13: ... Copy 30d to export the 30 days temperature data Connect USB storage device to the USB interface Choose USB Copy All to export the all data Choose View V I Batt to view the Choose View V I Batt to view the voltage current and battery state Choose About to view the device information Choose Advanced Set to set temperature limits The temperature limits are factory 12 The temperature limits are facto...

Page 14: ...wo TEC current 6 5A Alarm T1 T2 Shutoff TEC1 TEC2 Data Abnormities Sensor fault etc E1 TEC over temp TEC hot side temperature 80 C R1 Log failure Memory write error occurs 3 times M1 Memory failure Log memory initialization failure M2 Note If you find the above abnormalities please contact the customer service USB The device provides two USB interfaces USB1 provide data export function USB2 provid...

Page 15: ... the top of the device Figure 7 Need two people to lift the device Note Secure the device for transport Only for the empty device Do not transport the device when loaded with vaccines Transport the device Leave the device in its protective packaging as long as Leave the device in its protective packaging as long as possible to protect from damage Transport the device in protective packaging Transp...

Page 16: ...st filter Use water to clean and dry with a rag Replace after cleaning To clean the interior of the device 1 Use caution near the wires on the interior of the device these are for the sensors that monitor the internal temperature of the device 2 Remove the device s cap The cap will remain tethered to the device 3 Remove the vaccine stacks Follow established cold chain vaccine handling practices wi...

Page 17: ...g to clean Do not use corrosive solvents You need to use a duster as primary tool when it s not easy to get on the pole Note Please turn off the solar power switch on wall before cleaning Condensate If there s any condensate water you want to drain please use dry cloth to wipe up If there s too much please pour them out and wipe up 16 ...

Page 18: ... of vaccines to ensure that they keep properly cooled so as to remain potent and effective 2 Wait a moment until the interior of the device warms to above 2 C Alarm should no longer sound 3 Return vaccine stacks to the device and replace the cap If these steps don t work please call the customer service for help For higher temperature Check the screen display If there are other trouble codes liste...

Page 19: ...ccording to local regulation 2 The vacuum tank sealed tube removal or drilling in the tank shell to prevent use for 2 The vacuum tank sealed tube removal or drilling in the tank shell to prevent use for storing liquid nitrogen which would be dangerous 3 The plug is made by flammable material Keep away from flame during disposal 4 Tanks should be recycled by the local distributor and please contact...

Page 20: ...ou Three year warranty on the device included at no extra cost Under warranty coverage the manufacturer will repair or replace device components that have failed in the use of the device for its designed intent Free warranty coverage does not include the following cases Damage caused by improper use or improper maintenance Damage caused by attempted repairs done by a non designated repair departme...

Reviews: