ARKEL
133
ADrive
E
N
GLISH
T
Ü
R
KÇ
E
TOTAL TRAVEL:
0000358 RUN/STOP
TOTAL NUMBER OF TRAVEL SCREEN
The total number of travel of elevator in run/stop is displayed on this
screen.
CAN_BUS: 1920 p/s
RS485 : 800 p/s
SERIAL COMMUNICATION MONITORING SCREEN
CAN_BUS:
The number of packets per second of CANbus serial
communication between ENCABIT-Plus module and ADrive.
RS485:
The number of packets per second of RS-485 serial
communication (with ADrive Remote Keypad or lift controllers)
Vref : 1.20 m/s
Vact: 1.19 m/s
SPEED MONITORING SCREEN
Vref:
Reference (target) speed
Vact:
Actual (current) speed
Encabit PI:01000
Enc_pos : 001A3f22
ENCABIT-Plus MONITORING SCREEN
Encabit PI:
The state of the 5 digital inputs (PI1-PI5) on ENCABIT-
Plus module (1: input active / 0: input inactive).
PI1 PI2 PI3 PI4 PI5
Encabit PI: 0
1
0
0
0
Enc_pos:
The hexadecimal value of 21-bit absolute encoder position.
ADrive SW: V8.30
Encabit SW: V1.03
SOFTWARE VERSION SCREEN
The software version of ADrive inverter and ENCABIT-Plus module.
B.Resistor : % 4
**▪▪▪▪▪▪▪▪▪▪▪▪▪▪
BRAKING RESISTOR USING SCREEN
The using rate of braking resistor during braking.
Summary of Contents for ADrive VVVF
Page 1: ...ADrive VVVF Motor Sürücü VVVF Drive KULLANICI KILAVUZU USER MANUAL TR EN ...
Page 12: ...ARKEL ADrive 12 ENGLISH TÜRKÇE ...
Page 46: ...ARKEL ADrive 46 ENGLISH TÜRKÇE Uygun sigorta kontaktör ve kablo kesitleri için bkz Bölüm 6 ...
Page 50: ...ARKEL ADrive 50 ENGLISH TÜRKÇE ...
Page 80: ...ARKEL ADrive 80 ENGLISH TÜRKÇE 22 NOTLAR ...
Page 163: ...ARKEL 161 ADrive ENGLISH TÜRKÇE 22 NOTES ...
Page 166: ...TÜRKÇE ENGLISH Bu sayfa bilerek boş bırakılmıştır This page is intentionally left blank ...