ARITERM SWEDEN AB
•
ARITERM OY
• Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • 19.11.2009 • 21/32
Automatic convection cleaning system
The boiler is equipped with automatic convection cleaning system
that automatically carries out the sweeping at certain intervals. In
any case, the convection channels must be cleaned (swept) two
times a year. The cleaning is done through the cleanout hatch on the
top of the boiler. The automatic sweeping system must be removed
before sweeping. Disconnect the main power before maintenance
work.
Other boiler cleaning operations
Ash box emptying
Flue duct cleaning
Convection channel
cleaning 2 times a
year.
Combustion chamber cleaning
(as needed)
Convector cleanout hatch
Clean the flame detector of impurities.
NOTE!
If the protective glass of the flame detector breaks
or detaches, the flame detector can no longer be
used and must be replaced with a new one.
Remove all ash and possible sintering from the
combustion vessel. The primary air intakes and the
ignition resistance opening must be open.
Clean the metal pipe of the flame detector so that
the ash accumulated in the pipe will not hinder the
operation of the flame detector.
Pull the flame detector out of its pipe with caution
and hold on to the rubber lid.
BOILER CLEANING