background image

6

GB

Installation

!

 Before operating your new appliance please read this instruction booklet 

carefully. It contains important information for safe use, installation and care 

of the appliance.

!

 Please keep these operating instructions for future reference. Pass them on 

to possible new owners of the appliance.

Positioning

!

 Keep packaging material out of the reach of children. It can become a choking 

or suffocation hazard (see Precautions and tips).

!

 The appliance must be installed by a qualified professional according to the 

instructions provided. Incorrect installation may cause harm to people and 

animals or may damage property.

!

 This unit may be installed and used only in permanently ventilated rooms 

in accordance with current national regulations. The following requirements 

must be observed:

•  The room must be equipped with an air extraction system that expels 

any combustion fumes. This may consist of a hood or an electric fan that 

automatically starts each time the appliance is switched on.

In a chimney stack or branched flue. 

(exclusively for cooking appliances)

Directly to 

the Outside

•  The room must also allow proper air circulation, as air is needed for 

combustion to occur normally. The flow of air must not be less than 2 m

3

/h 

per kW of installed power. 

The air circulation system may take air directly 

from the outside by means of a pipe with an 

inner cross section of  at least 100 cm

2

; the 

opening must not be vulnerable to any type 

of blockages.

The system can also provide the air needed for 

combustion indirectly, i.e. from adjacent rooms 

fitted with air circulation tubes as described 

above. However, these rooms must not be 

communal rooms, bedrooms or rooms that 

may present a fire hazard.

•  Intensive and prolonged use of the appliance may necessitate 

supplemental ventilation, e.g. opening a window or increasing the power 

of the air intake system (if present).

•  Liquid petroleum gas sinks to the floor as it is heavier than air. Therefore, 

rooms containing LPG cylinders must also be equipped with vents to allow 

gas to escape in the event of a leak. As a result LPG cylinders, whether 

partially or completely full, must not be installed or stored in rooms or 

storage areas that are below ground level (cellars, etc.). It is advisable to 

keep only the cylinder being used in the room, positioned so that it is not 

subject to heat produced by external sources )ovens, fireplaces, stoves, 

etc. ) which could raise the temperature of the cylinder above 50°C.

A

Examples of 
ventilation holes 
for comburant air.

Enlarging the ventilation slot

between window and floor.

Adjacent

Room

Room to be

Vented

Fitting the appliance

The following precautions must be taken when installing the hob:

•  Kitchen cabinets adjacent to the appliance and taller than the top of the 

hob must be at least 200 mm from the edge of the hob.

•  Hoods must be installed according to their relative installation instruction 

manuals and at a minimum distance of 650 mm from the hob )see figure(.

•  Place the wall cabinets adjacent to the hood at a minimum height of 420 

mm from the hob )see figure(.

If the hob is installed beneath a wall cabinet, 

the latter must be situated at a minimum of 700 

mm above the hob.

•  The installation cavity should have the dimensions indicated in the figure.

  Fastening hooks are provided, allowing you to fasten the hob to tops that 

are between 20 and 40 mm thick. To ensure the hob is securely fastened 

to the top, we recommend you use all the hooks provided.

555 mm

55 mm

475 mm

Before the installation remove the grids and burners from the hob and turn it 

upside down, making sure you don’t damage the thermocouples and spark 

plugs.

Apply the seals that come with the 

appliance along the outer edges of 

the hob to prevent any passage of air, 

humidity and water (see Figure).

For proper application make sure the 

surfaces to be sealed are clean, dry and 

free of any grease/oil.

Hook fastening diagram

 

Hooking position for top 

H=20mm

  Hooking position for top 

H=30mm

 

 

Front

 

Hooking position for top 

H=40mm

 

Back

!

 Use the hooks contained in the “accessory pack”.

•  Where the hob is not installed over a built-in oven, a wooden panel must 

be installed as insulation. This must be placed at a minimum distance of 

20 mm from the lower part of the hob.

600mm min.

420mm min.

650mm min.

Summary of Contents for PKL 641 A

Page 1: ...Mode d emploi 1 Avertissements 2 Assistance 4 Description de l appareil 5 Installation 13 Mise en marche et utilisation 17 Pr cautions et conseils 17 Nettoyage et entretien 18 Anomalies et rem des 19...

Page 2: ...ur fonctionnement Ilfautfaireattention nepastoucher les l ments chauffants Ne pas faire approcher les enfants de moins de 8 ans moins qu ils ne soient soussurveillanceconstante Lepr sentappareilpeut t...

Page 3: ...o As opera es de limpeza e manuten o n o devem ser efectuadas por crian as sem vigil ncia ATEN O Deixarumfog ocomgordurae leosem vigil nciapodeserperigosoeprovocaruminc ndio NUNCA tente apagar as cham...

Page 4: ...stance Indiquez lui le type d anomalie le mod le de votre appareil Mod son num ro de s rie S N Ces informations figurent sur la plaquette signal tique appos e sur votre appareil et ou sur son emballag...

Page 5: ...respond le mieux au diam tre de votre casserole Manettes de commande des BR LEURS GAZ pour le r glage de la flamme La bougie d allumage des BR LEURS GAZ permet l allumage automatique du br leur s lect...

Page 6: ...t of a leak As a result LPG cylinders whether partially or completely full must not be installed or stored in rooms or storage areas that are below ground level cellars etc It is advisable to keep onl...

Page 7: ...ional regulations Before carrying out the connection make sure the cooker is compatible with the gas supply you wish to use If this is not the case follow the instructions indicated in the paragraph A...

Page 8: ...nt of discrete adjustment knobs with LED visualisation turn the knob to the minimum power setting them remove it and intervene on the adjustment screw located near the tap pin 7 Minimum setting adjust...

Page 9: ...liary A 100 75 55 36 130 0 70 0 40 0 40 0 30 1 50 2 60 1 65 1 00 0 90 3 60 39 28 28 29 29 57 80 64 50 44 44 60x2 189 120 73 65 262 186 118 71 64 257 2 60 1 65 1 00 0 90 3 60 122 H3 96 Z 79 6 74 74 94x...

Page 10: ...multaneously turn on both rings position the knob on the symbol max min then press and turn the knob anti clockwise To turn on the inner ring only position the knob on the symbol max min thenpressandt...

Page 11: ...you dispose of the appliance it must be separately collected Consumers should contact their local authority or retailer for information concerning the correct disposal of their old appliance Respectin...

Page 12: ...e gas holes on the burner are clogged All the movable parts that make up the burner are mounted correctly There are draughts near the appliance The flame dies in models with a safety device Check to m...

Page 13: ...d incendie Une utilisation intensive et prolong e de l appareil peut n cessiter d une a ration suppl mentaire comme par exemple l ouverture d une fen tre A Exemples d ouverture de ventilation pour l...

Page 14: ...que latensiond alimentationestbiencompriseentrelesvaleursindiqu essur la plaquette signal tique la prise est bien compatible avec la fiche de l appareil Si ce n est pas le cas remplacezlapriseoulafich...

Page 15: ...tige du robinet voir figure R glage DCDR int rieur R glage DCDR total 3 Une fois obtenu le d bit minimal souhait allumez le br leur et tournez brusquement la manette de la position de ralenti la posit...

Page 16: ...157 95 86 343 Br leur Diam tre mm Puissance thermique kW p c s R duit Puissance thermique kW p c s Nominale By pass 1 100 mm Injecteur 1 100 mm D bit g h Butane Propane Puissance thermique kW p c s N...

Page 17: ...composent le br leur ont une manette de commande Pour allumer les deux anneaux en m me temps appuyer sur la manette en tournant dans le sens inverse des aiguilles d une montre jusqu au symbole max mi...

Page 18: ...ironnement Faites cuire vos aliments dans des casseroles ou des po les couvercle et utilisez le moins d eau possible Faire cuire les aliments dans des casseroles ouvertes augmente consid rablement la...

Page 19: ...eur sont bien mont es correctement il y a des courants d air dans les environs du plan de cuisson La flamme s teint dans les versions quip es de s curit de flamme Avez vous contr l si vous avez bien a...

Page 20: ...asesdeliquefeitosdepetr leo maispesadosdoqueoar estagnam se embaixo Portanto as salas que contiverem cilindros de GLP devem possuir aberturas para fora de maneira que possibilitem o escoamento para ba...

Page 21: ...l ctrico e tomada da corrente deve ser f cil O cabo n o deve ser dobrado nem comprimido O cabo deve ser verificado periodicamente e substitu do somente por t cnicos autorizados veja aAssist ncia T cni...

Page 22: ...s aparelhos equipados com dispositivo de seguran a termopar em caso de n o funcionamento do dispositivo com os queimadores no m nimo aumenteacapacidadedospr priosm nimosmedianteoparafuso de regula o 5...

Page 23: ...36 130 0 70 0 40 0 40 0 30 1 50 2 60 1 65 1 00 0 90 3 60 39 28 28 29 29 57 80 64 50 44 44 60x2 189 120 73 65 262 186 118 71 64 257 2 60 1 65 1 00 0 90 3 60 122 H3 96 Z 79 6 74 74 94x2 248 157 95 86 3...

Page 24: ...ado cerca de 2 3 segundos at que aque a o dispositivo que mant m a chama automaticamente acesa Monocomando As coroas que comp em o queimador t m um bot o de comando Para acender ambas as coroas simult...

Page 25: ...consumidores devem contactar as autoridades locais ou os pontos de venda para solicitar informa o referente ao local apropriado onde devem depositar os electrodom sticos velhos Economia e respeito do...

Page 26: ...t o entupidos os furos de sa da do g s do queimador Est o instalados correctamente todos os componentes m veis que comp em o queimador H correntes de ar nas proximidades do plano A chama n o permanece...

Page 27: ...AR 27 3 2 2 100 50 200 650 420 770 40 20 555 mm 55 m m 4 7 5 m m 30 20 40 20 45 x 560 600mm min 420mm min 650mm min...

Page 28: ...28 AR 3 4 5 66 2014 2009 125 EC EN 30 2 1...

Page 29: ...AR 29 560 mm 45 mm 3 50 1 L 1 2 1 2 2000 1 7 2 1 3 4 1 7 2 1 3 1 2 DCDR DRDA...

Page 30: ...30 AR 5 2 3 5 5 1 2 3 RR 24 26 S 16 20 A 10 14 DCDR 10 14 DCDR 24 26 12 DCDR 3 l...

Page 31: ...28 64 120 118 1 65 96 Y 157 A 55 0 40 1 00 28 50 73 71 1 00 79 6 95 1 DCDR 36 0 30 0 90 29 44 65 64 0 90 74 86 1 DCDR 130 1 50 3 60 29 44 262 257 3 60 74 343 DCDR 2 57 60x2 94x2 28 30 20 35 37 25 45...

Page 32: ...32 AR WEEE 2012 19 EU 195145233 00 04 2016 XEROX FABRIANO Indesit Company S p A Viale Aristide Merloni 47 60044 Fabriano AN www hotpoint ariston com...

Reviews: