39
Servicing Instructions
10.5.5 Removing the pump
1.
Remove the electrical connection “ C1” (F
IG
. 10.44);
2.
Remove the allen screw “D1” (F
IG
. 10.45);
3.
Remove the pump (F
IG
. 10.46).
F
IG
. 10.44
F
IG
. 10.45
F
IG
. 10.46
10.5.6 Removing the pressure gauge
1.
Remove the U-clip “E1” (F
IG
. 10.47)
2.
Push the pressure gauge through the control panel from the
rear (F
IG
. 10.48).
E1
F
IG
. 10.48
F
IG
. 10.47
C1
D1
D1
D1
D1
Summary of Contents for INTESA TP23