5
3
DI
A
G
NOST
I
CS
5
3 0
Room Temperature Zone 2
only active when the BUS device is connected
5
3 1
Flow Temperatuyre Zone 2
Only active with Heating Zones Modules Management
5
3 2
Return Temperature Zone 2
Only active with Heating Zones Modules Management
5
3 3
Set Heating Temperature Zone 2
only active when the BUS device is connected
5
3 4
Heat Request Zone 2
0 = OFF - 1 = ON
5
3
5
Pump Status Zone 2
0 = OFF - 1 = ON
Only active with Heating Zones Modules Management
5
4
DI
A
G
NOST
I
CS
Only active with Heating Zones Modules Management
5
4 0
Operation Mode - Test
0 = OFF
1 = ON
3 = Manual
5
4 1
Valve control
0 = OFF
1 = open
2 = closed
5
4 2
Pump control
0 = OFF
1 = ON
5 5
MULT
I
ZON
E
Only active with Heating Zones Modules Management
5 5
0
Heating collector
temperature
from 0 to 120 (°C)
5 5
1
Heating collector fl ow outlet
temperature off set
from 0 to 40 (°C)
7 T
E
ST & UT
I
L
I
T
IE
S
7 0 0
Test Mode
t -- = Max Heating
power
t
--
= Max DHW power
t
--
= Minimum power
0
Enabled also by pressing for 10 seconds the Reset button.
This function is deactivated automatically after 10 minutes,
or when the RESET button is pressed.
7 0 1
Air purge Function
Press Menu/Ok button to
active
8 S
E
RV
I
C
E
PARAM
E
T
E
RS
8 1 S
E
RV
I
C
E
CO
DE
222
press the programming "+" button to select 234 and press the
M
ENU
button
8 2 BO
I
L
E
R
8 2 0
Set temperature Central
Heating(°C)
from 0 to 165 mA
8 2 1
Fun Status
0 = OFF - 1 = ON
8 2 2
NOT ACTIVE
8 2 3
Pump speed
0 = OFF
1 = Low speed
2 = High speed
8 2 4
Diverter valve position
0 = D.H.W.
1 = Central Heating
8 2
5
D.H.W. Flow Rate (l/min)
8 2 6
Air Pressure Switch Status
0 = Open
1 = Closed
8 3 BO
I
L
E
R T
E
MP
E
RTUR
E
8 3 0
Set temperature Central Heating(°C)
8 3 1
Flow Heating temperature (°C)
8 3 2
Return Heating temperature (°C)
8 3 3
Domestic Hot Water Temperature (°)
8 4 SOLAR & STORA
GE
8 4 0
Storage Temperature - NOT ACTIVE
D
isplay only with S
olar K
it or
ex
ternal stor
age K
it
8 4 1
Solar collector Temperature
8 4 2
D.H.W. Inlet Temperature
8 4 3
NTC Storage Low
8 4 4
Storage Set-point stratifi cation
8 4
5
Solar pump run time (hour/10)
8 4 6
Collector overheat Temp Time (hour/10)
8
5
S
E
RV
I
C
E
8
5
0
NOT ACTIVE
8
5
1
NOT ACTIVE
8
5
2
NOT ACTIVE
8
5
3
NOT ACTIVE
8
5
4
P.C.B Hardware version
8
5 5
P.C.B Software version
8
5
6
P.C.B BUS Software version
8 6 STAT
I
ST
I
CS
8 6 0
Hours Burner On (Central Heating) (XXh)
8 6 1
Hours Burner On (Domestic Hot Water) (XXh)
8 6 2
Number of Flame Faults
8 6 3
Numbeer of ignition Cycles
8 6 4
NOT ACTIVE
8 6
5
Heat request Duration
8 7 NOT ACT
I
V
E
8 8
E
RROR H
I
STORY
8 8 0
Last 10 errors
from E0 to E9
This parameter makes it possible to see the last 10 errors
shown by the boiler as well as the relevant day, month and
year. Access the parameter to bring up the sequence of errors
from number E00 to number E99.
The following data is shown in a sequence for each single
error:
E 00 - error number
1 08 - error code
A 15 - day when the error occurred E00
B 09 - month when the error occurred E00
C 06 - year when the error occurred E00
(only with remote control Clima Manager connected)
8 8 1
Reset Error List
Reset? Ok=Yes
Esc=No
Summary of Contents for CLAS B 28 FF
Page 1: ...Installation and Service Instructions CLAS B ...
Page 2: ......
Page 3: ...3 总 则 ...
Page 4: ...4 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 ...
Page 5: ...ø ø ø ø ø ø ø 312 ...
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ...安装 水路系统图 ...
Page 10: ...安装 单独 ...
Page 11: ...ø ø ø ø ø 28 ...
Page 12: ... ...
Page 13: ......
Page 14: ......
Page 15: ...15 1 a 3 c 2 b 4 d 试运行 燃气设置的检查 ...
Page 16: ......
Page 18: ...18 ...
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 54: ......
Page 55: ......