The boiler is protected from malfunctioning by means of internal
checks performed by the electronic microprocessor P.C.B., which
stops the boiler from operating if necessary.
In the event of the boiler being shut off in this manner, a code
appears on the display which refers to the type of shut-off and the
reason behind it.
There are two types of shut-off :
S
a
f
ety
shut
-
o
ff
This type of error is “volatile”, which means that the boiler starts up
again automatically as soon as the problem which caused the shut-
off is removed; on the display and fl ash “Err” and the error code (es:
Err
Err
/
101
101
).
In fact, soon as the cause of the shut-off disappears, the boiler starts
up again and continues to operate normally.
S
a
f
ety
shut
-
o
ff
due
to
insu
ffi
cient
w
ater
pressure
If the water pressure inside the heating circuit is
insuffi
cient, the boiler will perform a safety shut-off .
On the display fl ash “Err” and the code for Insuffi
cient water pressure
108
108
.
Check the water pressure on the pressure gauge and make sure
that is between 0.6 and1.5 bar when the system is cold. If the
pressure is just under the minimum refi ll the system by open the
valve under the boiler.
In this case or if the re-balancing request is performed on a frequent
basis, switch the boiler off , bring the external electric switch to
the OFF position, shut off the gas valve and contact a qualifi ed
technician to check for any leaks of water.
S
hutdo
w
n
This type of error is “non-volatile”, which means that it is not removed
automatically. On the display fl ash “Err” and the error code (es:
Err
Err
/
501
501
).To restore normal operation press the
button on the
control panel.
The fi rst fi gure of the error code (e.g. 1 01) indicates within which
operational assembly the error occurred.
1 - Primary Circuit
2 - Domestic Hot Water Circuit
3 - Internal Electronic Part
4 - External Electronic Part
5 - Ignition and Detection
6 - Air inlet - fl ue gas outlet
7 - Multizone
M
a
lf
unction
w
arning
This warning is shown by the display in the following format:
5 P3
5 P3
= Flame cut-off
the fi rst fi gure indicating the operational assembly is followed by a P
(warning) and the code relating to the specifi c warning.
Important
If this shutdown occurs frequently, contact an authorised Technical
Service Centre for assistance. For safety reasons, the boiler will
permit a maximum of 5 resets in 15 minutes (5 presses of the RESET
button); at the 6th attempt within this 15-minute period the boiler
will shut down and may only be operated again after the electricity
supply has been disconnected. If the shutdown is occasional or an
isolated event, this is not a problem.
C
entra
l H
eating
circuit
Display Description
1 01
Overheat
1 03
Insuffi
cient circulation
1 04
1 05
1 06
1 07
1 09
System pressure > 3 bar
1 10
C.H. Flow temp. probe circuit open / short circuit
1 08
Insuffi
cient water (request fi lling)
1 12
C.H. Return temp. probe circuit open / short circuit
1 14
External sensor circuit open / short circuit
1 18
Heating delevery probe problem
1 P1
Insuffi
cient circulation indication
1 P2
1 P3
D
.H.W.
circuit
2 01
D.H.W. temperature probe open / short circuit
2 02
Bottom storage temperature probe open / short circuit
2 04
Solar collector temperature probe open /
short circuit
S
olar K
it
(optional)
2 05
DHW In Probe Open Circuit
2 07
Solar collector overheating
2 08
Collector frost protection temperature
Interna
l P.C.B.’
s
3 01
EEPROM error
3 02
Comunication error
3 03
Main P.C.B. error
3 04
Too many (> 5) resets in 15 minutes
3 05
Main P.C.B. error
3 06
Main P.C.B. error
3 07
Main P.C.B. error
E
x
terna
l P.C.B.’
s
4 07
Room sensor circuit open 7 short circuit
Ignition
and
Detecion
5 01
No fl ame detected
5 02
Flame detected with gas valve closed
5 04
Flame lift
5 P3
Flame cut-off
A
ir
In
l
et
/
F
l
ue
gas
out
l
et
6 04
Insuffi
cient fan speed
6 07
Air pressure switch closed permanently
6 08
Air pressure switch OFF Fan ON
6 P1
Delay in air pressure switch closing
6 P2
APS close-open
M
u
l
ti
-z
one
H
eating
(H
eating
Z
one
M
odu
l
es
-
optiona
l)
7 01
Zone 2 outgoing sensor defective
7 02
Zone 2 return sensor defective
7 03
Zone 3 outgoing sensor defective
7 04
Zone 3 return sensor defective
7 05
Hydraulic separation sensor defective
7 06
Zone 2 overheating
7 07
Zone 3 overheating
T
a
bl
e
summarising
error
codes
Summary of Contents for CLAS B 28 FF
Page 1: ...Installation and Service Instructions CLAS B ...
Page 2: ......
Page 3: ...3 总 则 ...
Page 4: ...4 1 2 3 4 5 6 7 8 15 14 13 12 11 10 9 ...
Page 5: ...ø ø ø ø ø ø ø 312 ...
Page 6: ......
Page 7: ......
Page 8: ......
Page 9: ...安装 水路系统图 ...
Page 10: ...安装 单独 ...
Page 11: ...ø ø ø ø ø 28 ...
Page 12: ... ...
Page 13: ......
Page 14: ......
Page 15: ...15 1 a 3 c 2 b 4 d 试运行 燃气设置的检查 ...
Page 16: ......
Page 18: ...18 ...
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ......
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 54: ......
Page 55: ......