4.  Shower profile cold shower

a.  From Shower profile P3 setting, pressing again MODE button the user will go to set Shower cold 

shower, the shower icon P3 disappears, P0 will appear on temperature digits. The user will take 
the shower at inlet temperature (Show pict)

b.  Pressing again “MODE”   button the user exits from Programming Shower Profile function com-

ing back to manual temperature setting 

ECO FUNCTION SETTING

Pressing 

ECO

 button, ECO function will be activated. The product will start to work on energy saving 

mode decreasing the user household cost for taking shower guaranteeing the same and stable show-
er comfort.
a.  Firstly, press 

ECO 

button to start to operate ECO function and the Eco icon   will appear on the 

display

b. Pressing 

 or 

 the user is able to set its desired temperature from 

32

°

C

 to 

42

°

C

c.  Pressing again 

ECO

 button the user exits from ECO function coming back to manual temperature 

setting.

ELCB TEST (for ELCB models)

The built-in ELCB function will self-check every time before working, when the user turns “on” the 
electricity on the main switch out of the shower and the ELCB led will light up. It is recommended 
test at least once a month the correct ELCB functioning. After turn on the electricity and water supply:
1.  Press the 

TEST

 button;

2. 

ELCB led

 and SAFETY CHECK led will go off;

3.  Press the 

RESET

 button  to resume back the power supply.

If the ELCB led blinks and SAFETY CHECK led blinks or ELCB led does not light up and SAFETY CHECK 
blinks when the user presses the RESET button, the user has to switches off the main supply and con-
tact the service agent for repair. NEVER try to repair the unit by yourself.

CLEANING PRECAUTION

Do not use thinner, alcohol, petrol or any other organic solution to clean the set, use only a damp 
cloth with mild detergent.

CLEANING THE FILTER REGULARLY

There are two filters located at the water supply valve, one is mesh filter  (installed at the incoming 
water supply); the other one is the built-in filter as shown in fig.5.
Clean the two filters regularly to prevent blockage. Remove the built-in filter by turning it anti clock-
wise as shown in fig.5 B1. Take out the filter and flush it with water to remove any trapped sediments, 
as shown in fig.5 B2 - B3.
Note: the specification, actual product’s cosmetic design and accessories parts shown are correct at 
the time of printing and may be subjected to change without prior notice.

Others 

This innovative adjustable shower head has 5 and 3 different spray actions for constant temperature 
and non-constant temperature models, respectively.

Summary of Contents for AURES TOP 2,4

Page 1: ...ỚC NÓNG ĐIỆN TỨC THỜI ASSEMBLY AND OPERATION INSTRUCTIONS INSTANTANEOUS ELECTRIC WATER HEATER VI ELEKTRONIKONG SAGLIT NA PAMPAINIT NG TUBIG PH EN လက ငင းလျှပ စစ ရေပူရေပူ เครื องทำน ำอุ นไฟฟ าทันที MM PEMANAS AIR LISTRIK INSTAN ID TH RELEASE 15 06 22 ...

Page 2: ...n to play with the appliance User cleaning and maintenance may not be done by unsupervised children 8 Any repairs maintenance plumbing and electrical connection must be done by qa competent person using original spare parts only Failure to observe the above instructions can compromise the safety of the appliance and relieves the manufacturer of any liability for the consequences 9 The hot water te...

Page 3: ...cts falling off the appliance as a result of vibration 5 Do not climb onto the appliance Personal injury due to falling off the appliance Damage to the appliance or other property due to the appliance itself detaching from its mounting 6 Do not clean the appliance without having first isolated the electrical power supply to the unit Electrocution hazard due to the presence of live electrical equip...

Page 4: ...ent supply The use of a plug and socket is not recommended 2 For the correct size of wire conductor corresponding to different electrical loading please refer to table1 3 This heater operates at a minimum and maximum water pressure as per table ofTechnical Charac teristics 4 This heater will not function if there is insufficient water flow to trigger the flow switch 5 The built in ELCB will automa...

Page 5: ...washer 4 Hook the shower head to the shower hanger and adjust to your ideal position IMPORTANT THE WATER OUTLET CAN ONLY BE FITTEDTOTHE SOFT HOSE AND SHOWER HEAD SET PROVIDED NO CONTROL VALVE OR FITTING CAN BE MOUNTED TO THE WATER OUTLET Testing connection In the condition of without power supply turn on the water mains to drain out all plumbing dirt and to fill up the heater tank Check for any wa...

Page 6: ...ature and and HEATING icon will appear on display and hot water will start flowing from the shower head 5 Adjust the shower condition setting by a Press the plus button to increase the temperature or push minus button to decrease the temperature b Turn the product water supply valve in clockwise to increase the water flow decreasing the outlet water temperature or turn it in anticlockwise to decre...

Page 7: ...ent for repair NEVER try to repair the unit by yourself PROGRAMMING SHOWER PROFILE SETTING Pressing MODE button the shower programming profile will be activated Programming profile func tion allows to the user to memorize up to 3 shower temperature profile 1 Shower profile 1 a Firstly press MODE button to start to operate the Programming Shower Profile and the shower icon P1 will appear temperatur...

Page 8: ...ect ELCB functioning After turn on the electricity and water supply 1 Press the TEST button 2 ELCB led and SAFETY CHECK led will go off 3 Press the RESET button to resume back the power supply If the ELCB led blinks and SAFETY CHECK led blinks or ELCB led does not light up and SAFETY CHECK blinks when the user presses the RESET button the user has to switches off the main supply and con tact the s...

Page 9: ...ON 1 Increase temperature power setting 2 Ensure the water flow rate is not too big over 6L min by water supply valve if flow rate too big outlet water will not able to reach the setting temperature 3 Measure the actual voltage WHEN heating to make sure voltage drop not too big By increase section or reduce length of the power supply ca ble could improve 4 Ensure power supplier voltage not too sma...

Page 10: ...y hiểm đi kèm KHÔNGđượcđểtrẻemchơiđùavớithiếtbị Khôngđượcđểtrẻemtiếnhànhvệsinhvàbảotrìthiết bị mà không có sự giám sát 8 Mọithaotácsửachữa bảotrì bơmhoặcnốiđiệnphảidokỹthuậtviênđủtrìnhđộthựchiệnvàchỉsửdụng các linh kiện chính hãng Không làm theo hướng dẫn nêu trên có thể gây ảnh hưởng đến độ an toàn của thiết bị và khi đó nhà sản xuất sẽ không còn chịu bất kỳ trách nhiệm pháp lý nào đối với hậu qu...

Page 11: ...hỏi thiết bị do rung 5 Không trèo lên thiết bị Thương tích cơ thể do ngã từ thiết bị Hư hỏng thiết bị hoặc tài sản khác do thiết bị long khỏi giá treo 6 Không vệ sinh thiết bị khi chưa tắt rút phích cắm điện hoặc tắt công tắc nguồn của thiết bị Nguy cơ giật điện do có thiết bị điện còn mang dòng điện 7 Gắn thiết bị vào một bức tường vững chắc và không bị rung Nguy cơ thiết bị rơi khỏi tường do sập...

Page 12: ... Dimensions mm 416 x 200 x 81 5 HƯỚNG DẪN LẮP ĐẶT Chú ý trước khi lắp đặt 1 Máy phải được nối chắc chắn và trực tiếp với nguồn điện ổn định Không nên dùng phích cắm và ổ cắm điện 3 Sử dụng dây dẫn có kích cỡ phú hợp với từng loại công suất điện năng của máy Vui lòng tham khảo BẢNG 1 để chọn đúng kích thước dây dẫn 4 Bình đun nước nóng tức thời hoạt động với áp suất nước tối thiểu và tối đa theo bả...

Page 13: ...2 BSP 3 Nối ống mềm từ bộ vòi sen vào đầu nước ra hãy chắc chắn sử dụng đệm cao su 4 Treo vòi sen lên giá đỡ và điều chỉnh góc vòi sen thích hợp CHÚÝ CHỈ ĐƯỢC LẮP BỘVÒI SEN CẤP CÙNGVỚI BÌNHVÀO ĐẦU NƯỚC RA KHÔNG ĐƯỢC SỬ DỤNG BẤT KỲ LOẠIVAN ỐNG NỐI NÀO KHÁC Ở ĐẦU NƯỚC RA CỦA MÁY Kiểm tra kết nối Trong điều kiện không có nguồn điện mở nguồn nước để xả cặn trong máy và cấp nước trong bình đốt Kiểm tra...

Page 14: ...g đốt nóng sẽ hiển thị và nước nóng sẽ phun ra từ vòi hoa sen h 5 Điều chỉnh điều kiện tắm bằng cách a a Ấn nút cộng để tăng nhiệt độ hoặc ấn trừ để giảm nhiệt độ b Vặn van nước theo chiều kim đồng hồ để tăng lưu lượng giúp giảm nhiệt độ nước đầu ra hoặc vặn ngược chiều kim đồng hồ để giảm lưu lượng giúp tăng nhiệt độ nước đầu ra c Trong trường hợp nước đầu vào quá lạnh cả 2 phương án điều chỉnh s...

Page 15: ...n đầu ấn MODE để bắt đầu chương trình dữ liệu người dùng và biểu tượng P1 xuất hiện số hiển thị nhiệt độ nháy b Ấn hoặc để thay đổi nhiệt độ cài đặt c Đặt nhiệt độ phù hợp số hiển thị nhiệt độ sẽ nháy 3 giây sau đó sẽ cố định và ghi nhớ nhiệt độ dữ liệu người dùng P1 Người dùng luôn tắm với nhiệt độ cài đặt đó nếu đặt P1 2 Dữ liệu 2 a Đang ở dữ liệu P1 tiếp tục ấn nút MODE người dùng sẽ đi tới cài...

Page 16: ...HECK nháy hoặc đèn ELCB không sáng và đèn SAFETY CHECK nháy khi người dung ấn nút RESET người dung cần phải ngắt nguồn điện vào sản phẩm và liên hệ với dịch vụ sửa chữa KHÔNG ĐƯỢC thử tự sửa sản phẩm Chú ý KIỂM TRA ELCB thường xuyên LƯUÝ KHIVỆ SINH SẢN PHẨM Không được sử dụng cồn xăng chất tẩy rửa mạnh để làm sạch thiết bị chỉ nên dùng giẻ lau thấm chất tẩy loãng để lau sản phẩm VỆ SINH BỘ LỌC ĐỀU...

Page 17: ...ng nước không quá lớn trên 6L phút bằng cách chỉnh van tiết lưu nếu lưu lượng nước quá lớn nước đầu ra không thể đạt tới được nhiệt độ đặt 3 Đo điện áp thực khi sản phẩm ĐANG ĐUN để đảm bảo độ sụt điện áp không quá lớn Bằng cách tăng tiết diện hoặc giảm chiều dài dây cấp nguồn có thể cải thiện được việc sụt điện áp này 4 Đảm bảo điện áp cấp vào không quá bé bằng cách kiểm tra điện áp tại nhà khi K...

Page 18: ...en to play with the appliance User cleaning and maintenance may not be done by unsupervised children 8 Any repairs maintenance plumbing and electrical connection must be done by qa competent person using original spare parts only Failure to observe the above instructions can compromise the safety of the appliance and relieves the manufacturer of any liability for the consequences 9 The hot water t...

Page 19: ...ects falling off the appliance as a result of vibration 5 Do not climb onto the appliance Personal injury due to falling off the appliance Damage to the appliance or other property due to the appliance itself detaching from its mounting 6 Do not clean the appliance without having first isolated the electrical power supply to the unit Electrocution hazard due to the presence of live electrical equi...

Page 20: ...rent supply The use of a plug and socket is not recommended 2 For the correct size of wire conductor corresponding to different electrical loading please refer to table1 3 This heater operates at a minimum and maximum water pressure as per table ofTechnical Charac teristics 4 This heater will not function if there is insufficient water flow to trigger the flow switch 5 The built in ELCB will autom...

Page 21: ... washer 4 Hook the shower head to the shower hanger and adjust to your ideal position IMPORTANT THE WATER OUTLET CAN ONLY BE FITTEDTOTHE SOFT HOSE AND SHOWER HEAD SET PROVIDED NO CONTROL VALVE OR FITTING CAN BE MOUNTED TO THE WATER OUTLET Testing connection In the condition of without power supply turn on the water mains to drain out all plumbing dirt and to fill up the heater tank Check for any w...

Page 22: ...ature and and HEATING icon will appear on display and hot water will start flowing from the shower head 5 Adjust the shower condition setting by a Press the plus button to increase the temperature or push minus button to decrease the temperature b Turn the product water supply valve in clockwise to increase the water flow decreasing the outlet water temperature or turn it in anticlockwise to decre...

Page 23: ...ir NEVER try to repair the unit by yourself PROGRAMMING SHOWER PROFILE SETTING Pressing MODE button the shower programming profile will be activated Programming profile func tion allows to the user to memorize up to 3 shower temperature profile 1 Shower profile 1 a Firstly press MODE button to start to operate the Programming Shower Profile and the shower icon P1 will appear temperature digits bli...

Page 24: ...ning After turn on the electricity and water supply 1 Press the TEST button 2 ELCB led and SAFETY CHECK led will go off 3 Press the RESET button to resume back the power supply If the ELCB led blinks and SAFETY CHECK led blinks or ELCB led does not light up and SAFETY CHECK blinks when the user presses the RESET button the user has to switches off the main supply and con tact the service agent for...

Page 25: ...N ON 1 Increase temperature power setting 2 Ensure the water flow rate is not too big over 6L min by regulation valve if flow rate too big out let water will not able to reach the setting temper ature 3 Measure the actual voltage WHEN heating to make sure voltage drop not too big By increase section or reduce length of the power supply ca ble could improve 4 Ensure power supplier voltage not too s...

Page 26: ...en to play with the appliance User cleaning and maintenance may not be done by unsupervised children 8 Any repairs maintenance plumbing and electrical connection must be done by qa competent person using original spare parts only Failure to observe the above instructions can compromise the safety of the appliance and relieves the manufacturer of any liability for the consequences 9 The hot water t...

Page 27: ...ects falling off the appliance as a result of vibration 5 Do not climb onto the appliance Personal injury due to falling off the appliance Damage to the appliance or other property due to the appliance itself detaching from its mounting 6 Do not clean the appliance without having first isolated the electrical power supply to the unit Electrocution hazard due to the presence of live electrical equi...

Page 28: ...rent supply The use of a plug and socket is not recommended 2 For the correct size of wire conductor corresponding to different electrical loading please refer to table1 3 This heater operates at a minimum and maximum water pressure as per table ofTechnical Charac teristics 4 This heater will not function if there is insufficient water flow to trigger the flow switch 5 The built in ELCB will autom...

Page 29: ... washer 4 Hook the shower head to the shower hanger and adjust to your ideal position IMPORTANT THE WATER OUTLET CAN ONLY BE FITTEDTOTHE SOFT HOSE AND SHOWER HEAD SET PROVIDED NO CONTROL VALVE OR FITTING CAN BE MOUNTED TO THE WATER OUTLET Testing connection In the condition of without power supply turn on the water mains to drain out all plumbing dirt and to fill up the heater tank Check for any w...

Page 30: ...ature and and HEATING icon will appear on display and hot water will start flowing from the shower head 5 Adjust the shower condition setting by a Press the plus button to increase the temperature or push minus button to decrease the temperature b Turn the product water supply valve in clockwise to increase the water flow decreasing the outlet water temperature or turn it in anticlockwise to decre...

Page 31: ...ir NEVER try to repair the unit by yourself PROGRAMMING SHOWER PROFILE SETTING Pressing MODE button the shower programming profile will be activated Programming profile func tion allows to the user to memorize up to 3 shower temperature profile 1 Shower profile 1 a Firstly press MODE button to start to operate the Programming Shower Profile and the shower icon P1 will appear temperature digits bli...

Page 32: ...ning After turn on the electricity and water supply 1 Press the TEST button 2 ELCB led and SAFETY CHECK led will go off 3 Press the RESET button to resume back the power supply If the ELCB led blinks and SAFETY CHECK led blinks or ELCB led does not light up and SAFETY CHECK blinks when the user presses the RESET button the user has to switches off the main supply and con tact the service agent for...

Page 33: ...N ON 1 Increase temperature power setting 2 Ensure the water flow rate is not too big over 6L min by regulation valve if flow rate too big out let water will not able to reach the setting temper ature 3 Measure the actual voltage WHEN heating to make sure voltage drop not too big By increase section or reduce length of the power supply ca ble could improve 4 Ensure power supplier voltage not too s...

Page 34: ...en to play with the appliance User cleaning and maintenance may not be done by unsupervised children 8 Any repairs maintenance plumbing and electrical connection must be done by qa competent person using original spare parts only Failure to observe the above instructions can compromise the safety of the appliance and relieves the manufacturer of any liability for the consequences 9 The hot water t...

Page 35: ...ects falling off the appliance as a result of vibration 5 Do not climb onto the appliance Personal injury due to falling off the appliance Damage to the appliance or other property due to the appliance itself detaching from its mounting 6 Do not clean the appliance without having first isolated the electrical power supply to the unit Electrocution hazard due to the presence of live electrical equi...

Page 36: ...rent supply The use of a plug and socket is not recommended 2 For the correct size of wire conductor corresponding to different electrical loading please refer to table1 3 This heater operates at a minimum and maximum water pressure as per table ofTechnical Charac teristics 4 This heater will not function if there is insufficient water flow to trigger the flow switch 5 The built in ELCB will autom...

Page 37: ... washer 4 Hook the shower head to the shower hanger and adjust to your ideal position IMPORTANT THE WATER OUTLET CAN ONLY BE FITTEDTOTHE SOFT HOSE AND SHOWER HEAD SET PROVIDED NO CONTROL VALVE OR FITTING CAN BE MOUNTED TO THE WATER OUTLET Testing connection In the condition of without power supply turn on the water mains to drain out all plumbing dirt and to fill up the heater tank Check for any w...

Page 38: ...ature and and HEATING icon will appear on display and hot water will start flowing from the shower head 5 Adjust the shower condition setting by a Press the plus button to increase the temperature or push minus button to decrease the temperature b Turn the product water supply valve in clockwise to increase the water flow decreasing the outlet water temperature or turn it in anticlockwise to decre...

Page 39: ...ir NEVER try to repair the unit by yourself PROGRAMMING SHOWER PROFILE SETTING Pressing MODE button the shower programming profile will be activated Programming profile func tion allows to the user to memorize up to 3 shower temperature profile 1 Shower profile 1 a Firstly press MODE button to start to operate the Programming Shower Profile and the shower icon P1 will appear temperature digits bli...

Page 40: ...ning After turn on the electricity and water supply 1 Press the TEST button 2 ELCB led and SAFETY CHECK led will go off 3 Press the RESET button to resume back the power supply If the ELCB led blinks and SAFETY CHECK led blinks or ELCB led does not light up and SAFETY CHECK blinks when the user presses the RESET button the user has to switches off the main supply and con tact the service agent for...

Page 41: ...N ON 1 Increase temperature power setting 2 Ensure the water flow rate is not too big over 6L min by regulation valve if flow rate too big out let water will not able to reach the setting temper ature 3 Measure the actual voltage WHEN heating to make sure voltage drop not too big By increase section or reduce length of the power supply ca ble could improve 4 Ensure power supplier voltage not too s...

Page 42: ...en to play with the appliance User cleaning and maintenance may not be done by unsupervised children 8 Any repairs maintenance plumbing and electrical connection must be done by qa competent person using original spare parts only Failure to observe the above instructions can compromise the safety of the appliance and relieves the manufacturer of any liability for the consequences 9 The hot water t...

Page 43: ...ects falling off the appliance as a result of vibration 5 Do not climb onto the appliance Personal injury due to falling off the appliance Damage to the appliance or other property due to the appliance itself detaching from its mounting 6 Do not clean the appliance without having first isolated the electrical power supply to the unit Electrocution hazard due to the presence of live electrical equi...

Page 44: ...rent supply The use of a plug and socket is not recommended 2 For the correct size of wire conductor corresponding to different electrical loading please refer to table1 3 This heater operates at a minimum and maximum water pressure as per table ofTechnical Charac teristics 4 This heater will not function if there is insufficient water flow to trigger the flow switch 5 The built in ELCB will autom...

Page 45: ... washer 4 Hook the shower head to the shower hanger and adjust to your ideal position IMPORTANT THE WATER OUTLET CAN ONLY BE FITTEDTOTHE SOFT HOSE AND SHOWER HEAD SET PROVIDED NO CONTROL VALVE OR FITTING CAN BE MOUNTED TO THE WATER OUTLET Testing connection In the condition of without power supply turn on the water mains to drain out all plumbing dirt and to fill up the heater tank Check for any w...

Page 46: ...ature and and HEATING icon will appear on display and hot water will start flowing from the shower head 5 Adjust the shower condition setting by a Press the plus button to increase the temperature or push minus button to decrease the temperature b Turn the product water supply valve in clockwise to increase the water flow decreasing the outlet water temperature or turn it in anticlockwise to decre...

Page 47: ...ir NEVER try to repair the unit by yourself PROGRAMMING SHOWER PROFILE SETTING Pressing MODE button the shower programming profile will be activated Programming profile func tion allows to the user to memorize up to 3 shower temperature profile 1 Shower profile 1 a Firstly press MODE button to start to operate the Programming Shower Profile and the shower icon P1 will appear temperature digits bli...

Page 48: ...ning After turn on the electricity and water supply 1 Press the TEST button 2 ELCB led and SAFETY CHECK led will go off 3 Press the RESET button to resume back the power supply If the ELCB led blinks and SAFETY CHECK led blinks or ELCB led does not light up and SAFETY CHECK blinks when the user presses the RESET button the user has to switches off the main supply and con tact the service agent for...

Page 49: ...N ON 1 Increase temperature power setting 2 Ensure the water flow rate is not too big over 6L min by regulation valve if flow rate too big out let water will not able to reach the setting temper ature 3 Measure the actual voltage WHEN heating to make sure voltage drop not too big By increase section or reduce length of the power supply ca ble could improve 4 Ensure power supplier voltage not too s...

Page 50: ... E Water supply valve Van cấp nước F WATER OUTLET ĐẦU RA NƯỚC G Shower Hose Vòi hoa sen H Sliding Rail Đường ray trượt I Shower Hanger Móc áo tắm J Shower Head Đầu vòi hoa sen A Front Plate B Control Area C Filter D WATER INLET E Water supply valve F WATER OUTLET G Shower Hose H Sliding Rail I Shower Hanger J Shower Head ...

Page 51: ...0 ELCB Led 11 P1 P2 P3 shower programming icon 12 ECO button 13 Button water setting temperature 14 SAFETY CHECK button 1 Button to switch ON OFF 2 Button water setting temperature 3 MODE button 4 RESET button 5 TEST button 6 HEATING icon It lights on when heating 7 MAINTENANCE icon 8 ECO function incon 9 Temperature and quinck diagnostic 10 ELCB Led 11 P1 P2 P3 shower programming icon 12 ECO butt...

Page 52: ...utor board miniature circuit breaker MCB Cầu dao MCB Cầu dao MCB Cầu dao MCB Cầu dao MCB Cầu dao MCB ON OFF DP double pole Switch Double PVC cable ON OFF DP double pole Switch Double PVC cable ON OFF DP double pole Switch Double PVC cable ON OFF DP double pole Switch Double PVC cable ON OFF DP double pole Switch Công tắc chuyển 2 cực Dây PVC đôi 3 4 A ...

Page 53: ...ter unit cleaning Vệ sinh bộ lọc Filter unit cleaning Filter unit cleaning Filter unit cleaning Filter unit cleaning CLOSED Đóng OPEN OPEN CLOSED CLOSED OPEN OPEN CLOSED CLOSED B1 B B2 B3 Double PVC cable Dây PVC đôi Double PVC cable Double PVC cable Double PVC cable Double PVC cable Main Water Valve Van nước chính Main Water Valve Van nước chính Main Water Valve Van nước chính 5 ...

Page 54: ...Copper base 7 Connect pipe 8 Inlet Reed Switch 9 Outlet pipe 10 Outlet NTC 11 Heater tank 12 Bottom cover 13 Thermostat 1 Cầu đấu điện 2 Cuộn biến dòng ZCT 3 Bảng mạch chính 4 Bơm nếu có 5 Bảng mạch Triac Triac 6 Đế đồng 7 Ống nước nối 8 Cảm biến từ trường 9 Ống đầu ra 10 Đầu dò nhiệt 11 Bầu đun nước 12 Vỏ nhựa đế 13 Rơ le khống chế nhiệt ...

Page 55: ...rrent Current Current Current Conductor size Conductor size Conductor size Conductor size Conductor size Conductor size ON OFF Switch Sáng Tắt công tắc ON OFF Switch ON OFF Switch ON OFF Switch ON OFF Switch Fuse MBC Cầu chÌ MBC Fuse MBC Fuse MBC Fuse MBC Fuse MBC AC kW A mm Conduit cable Dây cáp Conduit cable Flexible Cable Dây mềm Flexible Cable A A 220V 3 5 15 9 2 5 7 0 67 mm 50 0 25 mm 20 20 2...

Page 56: ...Ariston S p A Viale Aristide Merloni 45 60044 Fabriano AN ITALY ariston com Produced by 420011260500 06 22 ...

Reviews: