60
7.5
A
CCESS TO THE
W
ATER
C
IRCUIT
7.5.1. R
EMOVING THE
D.H.W. (S
ECONDARY
) E
XCHANGER
(MFFI
ONLY
)
1.
Remove the two allen screws “A1” (F
IG
. 7.36);
2.
Push the exchanger towards the rear of the boiler, lift
upwards and remove from the front of the boiler (F
IG
.
7.37 - 7.38);
3.
Before replacing the exchanger ensure that the O-rings
are in good condition and replace if necessary.
Important!
Before any component is removed, the boiler
must be drained of all water.
F
IG
. 7.36
F
IG
. 7.37
F
IG
. 7.38
7.4.2. R
EMOVING THE SPARK GENERATOR
1.
Disconnect the electrical connection “Y” from the spark
generator (F
IG
. 7.34);
2.
Remove the screws “Z” from the bottom of the spark
generator (F
IG
. 7.35);
4.
Remove the spark generator.
F
IG
. 7.34
F
IG
. 7.35
Y
Z
A1
A1