55
F
IG
. 7.9
F
IG
. 7.10
H
G
I
I
1.
Disconnect the electrical connector “G” (F
IG
. 7.9);
2.
Disconnect the compensation tube “H” (F
IG
. 7.9);
3.
Unscrew the two screws “I” (F
IG
. 7.10);
4.
Remove the Air Pressure Switch
7.3.2. R
EMOVING THE
A
IR
P
RESSURE
S
WITCH
7.3.3. R
EMOVING THE
B
URNER
With the fan removed (see Section 7.3.1);
1.
Remove the four allen screws “J” (F
IG
. 7.11);
2.
Slide the burner from its housing (F
IG
. 7.12 - 7.13).
F
IG
. 7.11
F
IG
. 7.12
F
IG
. 7.13
J
Summary of Contents for ACO 27 MFFI