7.3.6. R
EMOVING THE
C
ONDENSATE
T
RAP
(
TUBE
)
1.
Open the clamp “Q” and remove the condensate trap
connection pipe (F
IG
. 7.25);
2.
Unscrew the screw “R” (F
IG
. 7.26);
3.
Remove the condensate tube.
7.3.7. R
EMOVING THE
C
ONDENSATE
T
RAP
1.
Remove the condensate trap tube (see section 7.3.6);
2.
Unscrew the screw “S” (F
IG
. 7.27);
3.
Remove the blanking cap “T” (F
IG
. 7.28);
4.
Remove the trap from the boiler.
NOTE:
Take care when removing the blanking cap to
place a container under the boiler as this will
release the contents of the condensate trap.
Q
R
S
T