The ACO RFFI (System) boiler is not supplied with a clock,
however a mechanical and digital clock is available as an
optional extra (mechanical - code: 706349 and digital - code:
706348)
To fit the clock it is necessary to proceed as follows:-
1. Remove the outer casing
2
. Open the control panel (see Section 2.22);
3. Unplug the electrical connection from the PCB and unscrew
the four screws (Fig. 2.26);
4. Remove the time clock (Fig. 2.27).
5. Connect the wires supplied with the clock to the digital time
clock as shown in Fig. 2.28;
6. Reassemble in reverse order.
3
2
1
G B
R
5 4 3
2
1
G
B
R
F
IG
. 2.28
D
IGITAL
M
ECHANICAL