46
/
SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
8
0
3
Boiler Life Time (h x 10)
8
0
4
Time of fan ON (h x 10)
8
0
5
Number of fan cycles (n x10)
8
0
6
Number of flame detection in CH (n x10)
8
1
7
Number of flame detection in DHW (n x10)
8
1
BOILER STATISTICS-2
8
1
0
Number of hours burner operating in heater mode (xxh/10)
8
1
1
Number of hours burner operating in hot water mode (xxh/10)
8
1
2
Number of flame separations (nr/10)
8
1
3
Number of ignition cycles (nr/10)
8
1
4
Average length of heating request (minutes)
8
2
BOILER
8
2
1
Fan Status
0 = OFF
1 = ON
8
2
2
Fan speed (x100) rpm
8
2
4
Diverter valve position
0 = D.H.W.
1 = Central Heating
8
2
7
Modulating Pump (%)
8
2
8
Gas Power (kW)
8
3
BOILER TEMPERTURE
8
3
1
Heating flow temperature (in °C)
8
3
2
Heating backflow temperature (in °C)
8
4
SOLAR & STORAGE
8
4
2
Solar appliance water input temperature
activated only with the solar kit
connected
8
5
SERVICE
8
5
0
Months to next maintenance
from 0 to 60 (month)
24
If setted the boiler will display that is time to call the installer for maintenance
8
5
1
Enable Maintenance advice
0 = OFF
1 = ON
0
8
5
2
Maintenance Warning Reset
Reset? OK= Yes Esc = No
to erase the advice for maintenance
8
5
3
2nd Heat Exchanger Clogging State
0 = DHW Exchanger OK
1 = Partially Clogged
2 = Very Clogged Please
Replace
8
5
4
PCB hardware version
8
5
5
PCB software version
8
6
ERROR LIST
8
6
0
10 last errors
from ERROR 0 to ERROR 9
This parameter allows the last 10 boiler errors flagged to be displayed, indicating the day, month and year.
When the parameter is accessed, the errors are displayed listed from ERROR 0 to ERROR 9.
For each error, the following sequence is displayed:
E00 - error number
108 - error code
8
6
1
Error list reset
Reset
OK = yes
ESC = no
menu
sub-menu
Parameter Description
value
default setting
Summary of Contents for 47-116-49
Page 61: ... 61 MAINTENANCE GUIDE Unscrew the four screws to remove the heat exchanger 9 10 11 ...
Page 76: ......
Page 79: ......