41
SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
menu
sub-menu
Parameter Description
value
default setting
SERVICE CODE
Press the button “+” to select code 234 and press o
k
. Turn the encoder to select MENU and press OK button
0
NETWORK
0
4
DISPLAY SETTING
0
4
0
Zone to be set by display
1 = 1 Zone
2 = 2 Zone
3 = 3 Zone
1
0
4
1
Backlight timing
from 0 to 10 (minutes) or 24
(hour)
24
0
4
2
Thermoregulation button deactivation
0 = OFF
1 = ON
0
2
BOILER PARAMETER SETTING
2
0
GENERAL
2
0
0
DHW Setpoint Temperature
from 36 to 60 (°C)
Setting by DHW button 2
2
0
1
DHW Pre-heating
0 = OFF
1 = ON
RESERVED FOR TECHNICAL
ASSISTANCE
Only if the PCB is changed
2
1
BOILER PARAMETERS
2
0
0
Boiler circulator type (NOT ACTIVE)
2
2
BOILER GENERAL SETTINGS
2
2
0
Soft ignition
from 0 to 90
60
See parag. Gas settings
2
2
3
Underfloor thermostat or zone 2 ambient
thermostat selection
0 = Floor safety thermostat
1 = Zone 2 ambient thermostat
0
2
2
4
Thermoregulation
0 = Absent
1 = Present
0
2
2
5
Heating ignition delay
0 = Deactivated
1 = 10 seconds
2 = 90 seconds
3 = 210 seconds
0
2
2
8
Boiler Version - CLAS ONE / CLAS ONE NET
CANNOT BE MODIFIED
from 0 to 5
0
RESERVED FOR TECHNICAL
ASSISTANCE
Only if the PCB is changed
Boiler Version - CLAS SYSTEM ONE
CANNOT BE MODIFIED
from 0 to 5
2
2
2
9
Set boiler heat power
2
3
BOILER PARAMETER - PART 1
2
3
1
Maximum heating power setting
from 0 to 99
60
see the “Gas setting” table,
information on Starting
2
3
2
Domestic hot water maximum percentage
CANNOT BE MODIFIED
from 0 to 99
RESERVED FOR TECHNICAL
ASSISTANCE
Only if the gas or PCB is
changed
see “gas setting” table
2
3
3
Minimum percentage
CANNOT BE MODIFIED
from 0 to 99
2
3
4
Heating maximum percentage
CANNOT BE MODIFIED
from 0 to 99
2
3
5
Selection of ignition delay type when
heating
0 = Manual
1 = Automatic
1
2
3
6
Ignition delay when heating timer setting
from 0 to 7 (minutes)
3
2
3
7
Post-circulation when heating
from 0 to 15 minutes or OC (AC)
3
2
3
8
<Not Available>
2
3
9
<Not Available>