71
TECHNICAL DATA
ErP Data - EU 813/2013
Model: CLAS SYSTEM ONE
18
24
30
Condensing boiler
yes/no
yes
yes
yes
Low-temperature boiler:
yes/no
no
no
no
B1 boiler
yes/no
no
no
no
Cogeneration space heater
yes/no
no
no
no
Combination heater
yes/no
no
no
no
Contact details
( Name and address of the manufacturer or its authorised representative)
ARISTON THERMO S.p.A.
Viale A. Merloni 45 60044
FABRIANO AN - ITALIA
ErP HEATING
Power output Pn
kW
18
22
28
Useful heat output at rated heat output and high-temperature regime P4
kW
18,0
22,0
28,0
Useful heat output at 30 % of rated heat output and low-temperature regime
(Return temperature 30°C) P1
kW
5,4
6,6
8,4
Seasonal space heating energy efficiency
η
s
%
93
94
94
Useful efficiency at rated heat output and high-temperature regime (60-80°C)
η
4
%
87,9
87,8
88,2
Useful efficiency at 30 % of rated heat output and low-temperature regime
(Return temperature 30°C)
η
1
%
98,5
97,2
98,7
AUXILIARY ELECTRICITY CONSUMPTION
At full load elmax
kW
0,024
0,030
0,039
At part load elmin
kW
0,014
0,014
0,015
In standby mode P
SB
kW
0,004
0,004
0,004
OTHER ITEMS
Standby heat loss Pstby
kW
0,039
0,039
0,043
Ignition burner power consumption Pign
kW
0,000
0,000
0,000
Sound power level, indoors L
WA
dB
51
49
51
Emissions of nitrogen oxides NOx
mg/kWh
57
53
51
PRODUCT FICHE -
EU 811/2013
Brand
Model
CLAS SYSTEM ONE
18
24
30
Seasonal space heating energy efficiency class
A
A
A
Power output Pn
kW
18
22
27
Annual energy consumption Q
HE
GJ
33
40
50
Seasonal space heating energy efficiency
η
s
%
93
94
94
Sound power level, indoors L
WA
dB
51
49
51
Brand
CLAS NET ONE
24
30
35
Seasonal space heating energy efficiency
η
s
%
94+3 =97
94+3 =97
94+3 =97
PRODUCT FICHE - CUBE S NET - WiFi Thermostat (CLAS NET ONE)
Brand
Supplier identification model
CUBE S NET
Temperature control class
V
Energy efficiency contribution for space heating %
3%
Important!!
The installation of the boiler and all the included thermoregulation accessories determines a final value of Seasonal space
heating energy efficiency (
ηs
) as shown in the table below for the various models.