Maximum domestic hot water fan speed (%)
CHANGE OF GAS TYPE
CHANGING OF THE TYPE OF GAS FROM
NATURAL GAS (G20) TO PROPANE GAS
(G31) OR REVERSE, IS PROHIBITED.
PUTTING INTO SERVICE
So set the parameters that interest you
(see settings menu).
Single zone installation (high temperature) with on / off room
thermostat and external probe:
To activate the function, enter a
parameter 224.
422 - Select the thermoregulation curve -
select the curve that interests you based on the type of
installation, appliance, thermal insulation of the building, etc.
in this case it is necessary to enter the parameters:
423 - The parallel movement of the curve - if applicable - can allow
you to lower or increase the set-point temperature (can also
be changed by the user with the heating temperature control
cap, which, if the Auto
function
is deactivated, has the role of
moving the curve in parallel).
For detailed information, refer to the
CHAFFOTEAUX Thermoregulation Manual.
Auto function
The function allows the boiler to automatically adapt to the operating
mode (radiator temperature) and to the external conditions, in order
to reach and keep the set ambient temperature constant.
421 - Activation Thermoregulation with sensors
Depending on the connected peripherals as well as the number of
zones controlled, the boiler automatically regulates the temperature
on the flow circuit.
- select 01 = external probe only
Example 2:
/
19
Minimum fan speed (%)
HS PREMIUM
60
3,07
30 EU
10
max heating
3,07
0,63
G20
83
231
Debit gaz max/min
83
Lower Wobbe Index (15 ° C, 1013 mbar) (MJ / m3)
45,67
234
max domestic hot water
Maximum heating power
Gas regulation table
35
2,4
24 EU
min
60
12
G20
2,4
0,44
Maximum fan heating speed (%)
220
233
45,67
82
Parameter
(15°C, 1013 mbari) (nat
- m3/h
Slow ignition
35
820
232
Machine Translated by Google