7 / EN
HEATING ELEMENT
Heating element power
V / W
Check product specification label
Max. water temperature with heating element
°C
75
Max. current consumption
A
11,48
POWER SUPPLY
Voltage / max. power consumption
V / W
Check product specification label
Frequency
Hz
50
Protection rating
IPX4
AIR SIDE
Standard air flow rate (automatic modulating control)
m³/h
650
Available static pressure
Pa
230
Minimum volume of room of installation (
D
)
m³
30
Minimum ceiling height of room of installation (
D
)
m
1,940
2,200
Min. temperature of room of installation
°C
1
Max. temperature of room of installation
°C
42
Minimum air temperature (w.b. a 90% u.r.) (
E
)
°C
-10
Maximum air temperature (w.b. a 90% u.r.) (
E
)
°C
42
Further energy data is shown in the Product Data Sheet (Annex A) which is an integral part of this booklet. Products that are not provided with a label
and corresponding product fiche for a combination of water heater and solar devices, as specified by Regulation 812/2013, are not intended to be used
for these kind of combinations.
(A) Values obtained with outdoor air temperature of 7°C and relative humidity of 87%, inlet water temperature of 10°C and temperature set at 55°C (as per the provisions in EN 16147).
Ducted product Ø200 mm,
(B) Values obtained with outdoor air temperature of 7°C and relative humidity of 87%, inlet water temperature of 10°C and temperature set at 55°C (as per the provisions of 2014/C 207/03 - transitional
methods of measurement and calculation). Ducted product Ø200 mm.
(C) Values obtained from the average of the results as per the provisions in EN 12102-2. Ducted product Ø200 mm.
(D) Value that guarantees the correct operation and easy maintenance with non-ducted products. The correct operation of the product is nevertheless guaranteed up to a minimum height of 2.090 m.
(E) Beyond the heat pump temperature range of operation, heating of the water is ensured by integration (as per provisions of EN 16147).