22 /EN
CAUTION!
Before intervening on the product by following the indications below, check the correct electrical connection of the components to the
mainboard and the correct position of the NTC sensors in their seats.
Error code
Cause
Heating element
operation
Heat pump
operation What to do
007
NTC Condenser: Open or Short Circuit
ON
OFF Verify NTC Condenser proper functioning
008
NTC Discharge (Compressor Outlet):Open or Short
Circuit
ON
OFF Verify NTC Discharge proper functioning
009
NTC Air: Open or Short Circuit
ON
OFF Verify NTC Air proper functioning
010
NTC Evap: Open or Short Circuit
ON
OFF Verify NTC Evap proper functioning
012
NTC Suction (Compressor Inlet): Open or Short Circuit
ON
OFF Verify NTC Suction proper functioning
021
Gas Leak
ON
OFF
Verify compressor inlet sensor proper functioning. If the error persists,
recover residual gas; find the leak in the cooling circuit; repair it; make
vacuum and recharge circuit with 1100g of refrigerant gas
032
Compressor Issue
ON
OFF Check power voltage on compressor connector.
042
Evaporator Obstructed
ON
OFF
Turn off the appliance.
Check that the evaporator and the external unit casing is not obstructed.
044
Fan Issue
ON
OFF
Check power voltage on fan connector.
Control the proper functioning of sensor at compressor inlet.
051
High Pressure
ON
OFF Check pressure switch wiring. Verify gas quantity.
053
Compressor Thermal Protector: KO
ON
OFF Check compressor thermal protector connector.
081
Electronic Expansion Valve Issue
ON
OFF
Verify expansion valve cables. Verify NTC suction and NTC Evap correct
functioning.
218
Dome NTC sensor (hot water): Open or Short Circuit
ON
OFF Verify NTC sensor (hot water) proper functioning
230
Water Temperature Sensor (Heating Element Zone):
Open or Short Circuit
OFF
OFF
Check the correct assembly of sensor wiring on related mainboard
connector.
Verify sensor proper functioning.
231
Water Temperature sensor (Heating Element Zone):
safety intervention (1st level).
OFF
OFF Verify sensor proper functioning.
232
Water Temperature sensor (Heating Element Zone):
safety intervention (2nd level).
OFF
OFF Verify sensor proper functioning.
233
Relay blocked
OFF
OFF
Reset the appliance by pressing the ON/OFF button twice. If the error per-
sists, replace the motherboard.
314
ON / OFF repeated
OFF
OFF Wait 15 minutes before unlocking the product with ON/OFF button
321
Corrupted data
OFF
OFF
Reset the product by pressing the ON / OFF button twice.
If the error persists, replace the motherboard.
DEFAULT SETTINGS
The appliance is manufactured with a series of default modes, functions or values, as indicated in the table below:
PARAMETER
FACTORY DEFAULT SETTING
WORKING MODE
GREEN
DEFAULT SET TEMPERATURE
55 °C
MAX. TEMPERATURE SETTABLE WITH THE HEATING ELEMENT
75 °C
MINIMUM SETTABLE TEMPERATURE
40 °C
MAX. TEMPERATURE SETTABLE WITH THE HEAT PUMP
62 °C
ANTIBACTERIAL FUNCTION
DEACTIVATED
HOLIDAY MODE
DEACTIVATED
DEFROST (active defrost activation)
ACTIVATED
HC-HP (two-tier rate operation mode)
DEACTIVATED
HYSTERESIS
12°C
FAULTS
As soon as a fault occurs, the appliance enters into the fault mode while the display emits flashing signals and visualises the error code. The wa-
ter heater will continue supplying hot water if the fault affects only one of two the heating units, by activating the heat pump or heating element.
If the fault involves the heat pump, the symbol "HP" will flash on the screen, while the heating element symbol will flash if the fault involves it. If
both components are affected, both symbols will flash.
Summary of Contents for 200D
Page 1: ...IT HEAT PUMP WATER HEATER Instructions for installation use maintenance 200D 250I ...
Page 26: ...26 EN 32 8 BENChMARK COMMISSIONING ChECKLIST ...
Page 27: ...27 EN 33 9 BENChMARK SERVICE RECORd ...
Page 29: ...29 EN ...
Page 30: ...30 EN ...
Page 31: ...31 EN ...