5 / EN
PRODUCT DESCRIPTION
The floor-standing heat pump water heater consists of a top block
containing the heat pump unit and the bottom part of the with the
storage tank. There is a control panel with a display on the front
part.
Dimensions
A
Inlet cold water ¾” connection
B
Outlet hot water ¾” connection
C
Condensate drain connection with 14mm diameter
D
Auxiliary circuit ¾” inlet pipe (SYS and TWIN)
E
Auxiliary circuit ¾” outlet pipe (SYS and TWIN)
F
Sheath for upper probe (S3) (SYS and TWIN)
G
Auxiliary circuit ¾” inlet pipe (TWIN SYS)
H
Auxiliary circuit ¾” outlet pipe (TWIN SYS)
I
Sheath for upper probe (S4) (TWIN SYS)
L
Recirculation ¾” pipe (SYS and TWIN SYS)
M
Sheath for bottom probe (S2) (SYS and TWIN SYS)
N
Display
O
Touch buttons.
MODE
MENU
SET
376
550 (200L) - 810 (250L)
1737 (200L) - 1997 (250L)
1220 (200L) - 1480 (250L)
371
290
980
1074
113
204
680
650
600
371
OUT
IN
OUT
IN
A
A
M
F
F
B
B
L
G
H
L
I
I
D
C
E
O
N
11
12
13
14
15
10
8
7
6
5
4
3
2
1
9
16
17
1
Fan
2
Hot gas valve
3
Safety pressure switch
4
Electronic expansion valve
5
Evaporator inlet NTC temperature probe
6
Electronic box
7
Bottom NTC temperature probe (heating element zone)
8
Electric heating element
9
Top NTC temperature probe (hot water)
10
Hermetic rotary compressor
11
Condensate drain pipe
12
Lateral connections
13
Low pressure outlet
14
Air NTC temperature probe
15
Compressor suction NTC temperature probe
16
Evaporator filter
17
Evaporator
Main components