6 /EN
TECHNICAL DATA TABLE
DESCRIPTION
Unit
200 D
250 I
Rated tank capacity
l
200
245
Insulation thickness
mm
≈ 50
Type of internal tank protection
Enamelling
Type of corrosion protection
Disposable magnesium anode
Maximum operating pressure
MPa
0,6
Diameter of hydraulic connections
II
G 3/4 M
Diameter of condensate drainage connection
mm
14
Diameter of air exhaust/intake pipes
mm
150-160-200
Minimum water hardness
°F
12
Minimum conductivity of the water
μS/cm
150
Weight when empty
kg
90
123
Weight when filled with water
kg
290
365
CYLINDER (EN 12897:2016+A1:2020)
Normal operating pressure
bar
3,5
3,5
Maximum water supply pressure
bar
12
12
Cold connection (feed)
¾’’ G
¾’’ G
Hot connection (draw off)
¾’’ G
¾’’ G
Pressure Reducing Valve Set Pressure
bar
3,5
3,5
Cylinder TPRV
°C/bar
90-95/ 7
90-95/ 7
Combination valve PRV
bar
6
6
Expansion vessel pre-charge pressure
bar
3,5
3,5
Operating temperature of not-resetting thermostat
°C
--
30-70
CYLINDER INDIRECT COIL (EN 12897:2016+A1:2020)
Connections
--
¾’’ G
Surface area
m2
--
0,65
Volume coil
m3
--
0,0047
Maximum supply pressure
bar
--
6
Rating @60°C
l
--
181,9
Primary flow rate
l/min
--
15
Pressure drop through coil @15l/min
mbar
--
18
Primary heating power input
kW
--
9,76
Heating time from 15°C to 60°C
min
--
58:40
Max water temperature with external integration
°C
--
75
HEAT PUMP
Average electrical power consumption
W
700
Max. electrical power consumption
W
900
Quantity of refrigerant fluid (R134a)
kg
1,3
Quantity of fluorinated greenhauses gases (R134a)
Tonn. CO
2
eq.
1,859
Global warning potential (R134a)
GWP
1430
Max. pressure of refrigerating circuit (low-pressure side)
MPa
1
Max. pressure of refrigerating circuit (high-pressure side)
MPa
2,7
Max. water temperature with heat pump
°C
62
EN 16147 (
A
)
COP (
A
)
3,10
3,14
Heating time (
A
)
h:min
03:59
05:24
Heating energy consumption (
A
)
kWh
2,478
3,264
Max. amount of hot water in a single intake Vmax (
A
), delivered at 55°C
l
256
333
Pes (
A
)
W
21
23
Tapping (
A
)
L
XL
812/2013 – 814/2013 (
B
)
Qelec (
B
)
kWh
3,72
6,04
η
wh (
B
)
%
130,0
129,0
Mixed water at 40°C V40 (
B
)
l
256
333
Temperature setting (
B
)
°C
55
55
Annual electricity consuption (average climatic condition) (
B
)
kWh/year
790
1299
Load prifile (
B
)
L
XL
Indoor sound power level (
C
)
dB(A)
55
55
Summary of Contents for 200D
Page 1: ...IT HEAT PUMP WATER HEATER Instructions for installation use maintenance 200D 250I ...
Page 26: ...26 EN 32 8 BENChMARK COMMISSIONING ChECKLIST ...
Page 27: ...27 EN 33 9 BENChMARK SERVICE RECORd ...
Page 29: ...29 EN ...
Page 30: ...30 EN ...
Page 31: ...31 EN ...