Overview
Specifications
Quick Start Guide: 7000 Series 1 RU-Gen 3 Data Center Switches
5
Note
RJ-45 to DB-9 connections: Models with management ports on the rear panel short RJ-45 pin 1 (RTS)
to RJ-45 pin 8 (CTS). RJ-45 pins 2 (DTR) and RJ-45 pin 7 (DSR) are not electrically connected to
anything.
Operating Temperature
Storage Temperature
Operating Altitude
Relative Humidity
all
all
all
all
0° to 40° C (32° to 104° F)
-25° to 70° C (-13° to 158° F)
0 to 3,000 meters (0 to 10,000 feet)
5 to 90% (non-condensing)
Power Input (AC Power)
PWR-500-AC
PWR-745-AC
PWR-747-AC
100 - 240 VAC, 10.0 - 5.0 A, 50/60 Hz
Power Input (DC Power)
PWR-500-DC
PWR-1900-DC
-48 to -60 VDC, 15 A
-48 to -60 VDC, 24 A
Power Draw
(Typical / Maximum)
DCS-7050QX-32S
DCS-7050SX-64
DCS-7050SX-72
DCS-7050SX-96
DCS-7050TX-48
DCS-7050TX-64
DCS-7050TX-72
DCS-7050TX-96
DCS-7280SE-64
DCS-7280SE-68
DCS-7280SE-72
DCS-7280QR-C36
DCS-7050SX-72Q
DCS-7280SR-48C6
DCS-7280TR-48C6
DCS-7060CX-32S
DCS-7050QX2-32S
DCS-7050SX2-72Q
DCS-7050TX-72Q
DCS-7160-32CQ
DCS-7160-48YC6
DCS-7160-48TC6
DCS-7280SR2-48YC6
DCS-7280SR2A-48YC6
DCS-7020TR-48
DCS-7280SRA-48C6
DCS-7060CX2-32S
150 W / 300 W
140 W / 220 W
144 W / 276 W
159 W / 290 W
305 W / 367 W
315 W / 387 W
349 W / 440 W
355 W / 455 W
263 W / 381 W
313 W / 405 W
262 W / 399 W
324 W / 499 W
144 W / 261 W
263 W / 381 W
290 W / 405 W
220 W / 410 W
129 W / 283 W
127 W / 251 W
340 W / 430 W
311 W / 466 W
168 W / 382 W
400 W / 500 W
425 W / 647 W
450 W / 685 W
105 W / 115 W
314 W / 410 W
220 W / 410 W
Table 1-1 Switch Specifications (Continued)