PiCUS TreeQinetic Manual
40
7 Technical Information
NiMH rechargeable batteries are used in all devices of the system with built-in batteries.
7.1 PTQ Com Unit
Property
Value
general
Weight
690 g
Dimensions
150 mm x 100 mm x 70 mm
Battery
Capacity
2000 mAh
Runtime (in usual conditions)
10 h
Max. charging current
800 mA
Charge time
Ca 2,5 h
Recommended charge temperature
5
– 35 °C (ambient temperature)
Max. temperature range
0
– 40 °C (ambient temperature)
Communication
To mobile device
Bluetooth 5.0 (partially 4.2)
Long-range-mode depending on mobile device
To PC
USB 2.0 / Bluetooth 5.0 Dongle
Charge channels
3 channels for modules
each 800 mA
7.2 PTQ Forcemeter
Property
Value
general
Weight
1970 g
Dimensions
235 mm x 75 mm x 60 mm
Battery
Capacity
2000 mAh
Runtime (in usual conditions)
ca. 15 h
Charging mode
Via com unit or eightfold charger
Max. charging current
800 mA
Charge time
ca. 2,5 h
Recommended charge temperature
5
– 35 °C (ambient temperature)
Max. temperature range
0
– 40 °C (ambient temperature)
Measurement
Accuracy force
0,3 kN
Resolution force
0,01 kN
Range force
0 - 60 kN
Accuracy rope angle
1° (0-30°)
Resolution rope angle
0,1°
Range rope angle
0
– 90°
Acceptable temperature range
-20
– +50 °C
Accuracy voltage
0,01 V
Communication
Radio connection
868 MHz, 14 dBm, 115,2 kBps
Range at free line of sight > 150 m