PiCUS TreeQinetic Manual
34
5.7.2 Page
– Forcemeter
This page displays the recorded data curves of all forcemeters involved in the measurement
in a line diagram.
By tapping the buttons below the diagram the data display of each forcemeter can be adjusted:
•
F & A
Force and rope angle curves [kN] and [°] are displayed
+ the markings for the determined maximum force and the rope angle averaging
window
•
Force
Only the force data curve is displayed in [kN]
+ the marking for the determined maximum force (see
•
Angle
Only the rope angle curve is displayed in [°]
+ The marking for the rope angle averaging window
•
Off
No curve is displayed
The diagram display can also be zoomed using the usual 2-finger pull gesture on both axes.
This applies to all diagrams of the
Data View
tab.
The magenta colored line represents the alarm limit set for the forcemeters.
NOTE
The X-axis / time axis runs continuously, so if the data recording is paused during the
measurement and continued later, the measurement curves will also have corresponding blank
areas.
This applies to all diagrams of the
Data View
tab.
5.7.3 Page
– Elastometer
This page displays the recorded data curves of all elastometers involved in the measurement
in a line diagram.
By tapping the buttons below the diagram the data display of each elastometer can be
adjusted:
•
On
Strain curve is displayed in [µm]
•
Off
Curve is not displayed
The two magenta colored lines represent the alarm limit (positive and negative) set for the
elastometers.