R-Series Technical Manual
Rev. 1.02 November 24, 2008
Argox Information Co., Ltd.
36
Out of ribbon indication:
Status
LED
Description
RIBBON OUT
RIBBON
READY
The ribbon is not installed or out of ribbon.
Switch power off
Out of ribbon?
No
Ribbon stuck
or jammed
No
Ribbon is
moving during
printing?
No
Check mechanism
Yes
Yes
Yes
Check the ribbon sensor.
Replace with new sensor
if necessary.
Remove the stuck or
jammed ribbon
Load a new ribbon
Switch power on
then start printing