eep backup data file clip
Before the flash is erased, the static eep value of the MS will be stored in the
EEP_Backup file clip of which the file name is “Serial number” and the sub-file name is
“eep”, and after the erase step, if the download is failed, you can click this backup to
renew the value in the static eep of the phone. In the process, Temp*.eep, Temp*.epp
and the like will be created in the EEP_Backup, and when the download is successful,
the files will be canceled automatically; if they remains, the user can directly cancel
them, but do not cancel them during download.