PECA30 / 30
E : general presentation
12
ARDETEM
DISPLAYED ABBREVIATIONS LIST ON THE DIFFERENT MENUS :
Acc
:
increase in energy witch provides a pulse
AFF
: display
programming
AFF. OFF
:
auto extinguishing of the display, after 5 min.
AnA
:
3 analog outputs board (current)
ANA.A
:
3 analog outputs (current) + 2 alarm outputs mixed board
ANA.P
:
3 analog outputs (current) + 2 pulse outputs mixed board
bAUd
:
transmission speed (for the serial interface) (baud rate)
brd
: optional
board
CAL
: voltage
calibre
CAL Urn
:
simple voltage calibre (for the network Nr: 4)
CAL UrS
:
mesh voltage calibre (for the network Nr: 2,3 et 5)
CALC
:
message displayed during the harmonic calculation
CLr
: reset
CLr.E
:
energies reset
CLr.C
:
(current, power…) peak value reset,
CLr.H
:
running time-meter reset
CLr.m
:
measurement time saving reset
conF
:
all PECA configuration
dEC.U (dEC.I)
:
running time-meter set of the UTR or IR presence
dEL
:
threshold relay commutation delay or pulse time delay
dISP
:
functions about the display (alarms display, automatic extinguishing,…)
EA.O1 (EA.O2)
:
active energy out meter 1 : normal ( meter 2 : ex: for EJP )
EA.I1 (EA.I2)
:
active energy in meter 1 : normal ( meter 2 : ex: for EJP )
ELEC
:
electrical cosinus (YES) or mathematical (no)
EnEr
:
energies setting, or capture value from the front key of the PECA
Er.O1 (Er.O2)
:
reactive energy out meter 1 : normal ( meter 2 : ex: for EJP )
Er.I1 (Er.I2)
:
reactive energy in meter 1 : normal ( meter 2 : ex: for EJP )
Err
:
configuration, wiring ...errors visualization
ESCL
:
Modbus/Jbus slave number for the serial interface
F. num.
:
measurement logic filtering
FIL.num
:
total measurement filtering
FIL.PIC
: peaks
elimination
HAr.U (HAr.C)
:
Utr voltage harmonic (Ir current)
HI (LO)
:
high saturation (HIgh) or low saturation (LOW)
hour
: time-meter
setting
HYS
:
threshold relay hysteresis
I mA
:
current output scale in mA
JBUS
:
Modbus / Jbus optional board
PArA
:
measurement parameter number (see page 13)
P dS ( P FS )
:
Parameter down and Full Scale
PULS
:
3 pulse outputs board
P tC ( P tP )
:
primaries of the current, voltage external transformer
rAP
:
external current, voltage transformer ratio
rEAd
:
PECA configuration (programming) reading
rEC. (gEN.)
:
network current sense, the load is receiver (generator) of current
rEEL
:
pattern Modbus transmission in real (floating decimal point) or double integer
rES
:
measured network (rES Nr..:= network type)
SAVE
: captured
configuration
saving
ScrL
:
auto scrolling of the pages (scroll)
S tC
( S tP )
:
secondaries of the current, voltage external transformer
SECU
:
threshold relay security or output current saturation in case of alarm
SEnS
:
current sense (the load is generator or receiver of current)
Sor.1
:
Nr 1 output (optional board)
SP 1 ( SP 2 )
:
relay threshold 1 (threshold 2 )