ACE-SDC-V3 Manual
page 25
rev 1.08
b. ACCEL
– Motor is accelerating.
c. DECEL
– Motor is decelerating.
d. CONST
– Motor is moving at constant speed.
3. Current
Displays current value.
4. AI
Displays current analog input value (10 bit)
Range is 0 to 1023 which corresponds to 0 to 3.3V.
8.1.2. Control
Figure 8.3
1. Target Position
– Used to move the motor to the target position.
2. Speed
– Set high speed setting of the motor (up to 16Kpps).
3. Accel
– Set acceleration time (up to 300ms).
4. Enable Status
– Displays the energized status of the motor
5. Datum
– Moves the motor back to the zero position.
6. ABS
– Moves the motor to the target position.
7. JOG-
– Jogs the motor in the minus direction.
8. JOG+
– Jogs the motor in the plus direction.
9. STOP
– Stops the motor.
8.1.3. Digital Input
Figure 8.4
Displays the current digital input status. When used in DIO control mode, each
input is designated for specific use: