background image

All possible precautions must be taken in order to avoid stray current. 
Connect gas pipe to pressure reducer output connected to an ARGON cylinder. 
Regulate gas flow adjusting the regulation knob on the torch handle. 
Inside the torch handle a valve allows the gas flow to be shut. 
Use a 2% thoriated tungsten electrode having a diameter chosen according the negative electrode direct current (Argon) value 
as follows: 

up to 60A           diam. 1 mm

60A to 180A       diam. 1.6 mm

180A to 250A      diam. 2,4 mm 

The electrode tip should be prepared for welding according to procedure indicated hereafter. 
Check the main supply voltage to match the voltage on the power supply technical specification tag. 
Connect main supply cable: when mounting a plug make sure that its capacity is adequate and that the yellow-green wire of the 
mains cable is connected to the earth plug pin. 
The capacity of the magnetothermic switch or the fuses in the mains supply line should be higher than or equal to current I

1

absorbed by the unit. 
The absorbed current I

1

 is determined by dividing by 1.6 the value stated on the table. 

Any extension cord should have a section adequate for the absorbed current I

1

.

Set welding current based on the weld to be performed then adjust the gas flow with knob on torch handle. 
Start the arc, by contact, with a quick scratch on the surface to be welded. 
CAUTION do not use commercial ignition devices. 
The TIG torch is designed in such a way that using the valve on the torch body the gas flow can continue after the weld is 
performed to protect the electrode while it is still hot. 
After the proper amount of time /few seconds) the gas flow can be stopped by shutting the valve on the torch handle. 
Once welding is finished the unit is to be turned off and the gas cylinder valve is to be closed. 

TIG HF 

On the front of the control panel the following can be found 
1.  Welding current regulation potentiometer 
2.  Holder/torch and earth sockets 
3.  Current manual setting/remote control lever switch 
4.  TIG/MMA welding lever switch 
5.  Digital A-meter to read the current draw upon arc ignition 
6.  Current rise time regulation knob 
7.  Current fall time regulation knob 
8.  Current Post-gas time regulation knob 
9.  Socket for remote control connection 
10.  2 time/4 time operation mode lever switch 
11. Gas outlet 
12.  Torch push-button connector 
Five LED warning lights on the left side of the front panel signal the following, respectively: 
A.  Generator under voltage (GREEN LED)  
B.  Line surge or overheating (YELLOW LED) 
C.  High frequency igniter on (RED LED) 
D.  Argon gas supply (GREEN LED) 
E.  Inverter on (YELLOW LED) 

This welding machine is suitable for TIG welding of inox steel, iron and copper. Connect the earth cable connector to the positive 
terminal of the welding machine and the clamp as close as possible to the welding spot, making sure good electrical contact is 
made. Use the special TIG torch (for HF ) and connect the power connector to the negative terminal of the welding machine. The 
welding circuit must not be put into direct or indirect contact with the safety conductor except on the work piece. If the work piece 
is deliberately earthed through the safety conductor having a section equal to or greater than that of the welding current return
conductor connected to the work piece at the same point as the return conductor with the return conductor clamp or another 
earth  clamp next to it. Take the utmost care  to avoid welding stray currents. Connect the gas inlet on the rear panel of the 
generator to the output of the pressure reducer connected to an argon cylinder. Adjust the gas pressure by means of the flow 
meter. Use a 2% thoriated tungsten electrode chosen according to the following table: 

up to 60 A

‡

 1.0 mm 

from 60 A to 180 A

‡

 1.6 mm 

The preparation of the electrode tip should be done as explained in the following. Check that the supply voltage is the one 
indicated on the technical specification plate of the welding machine. Connect the power cable. Switch on the welding machine 
by closing the power switch on the rear panel; adjust the current according to the job to be carried out, set switch 2/4T to 4T
mode, set the current rise and fall times as preferred and the post-gas time; then bring the electrode within 3 mm approximately
from the work piece and let out a pulse upon pressing the torch push-button (press and release it). The following will occur: 
1.  Gas is let out and the relevant LED lights up. (LED D) 
2.  The high frequency circuit stars (within a second or so and ignites an arc) (LED C) 
3.  Current rises until it reaches the value set, as the A-meter will show. 
At this stage, the generator will keep the arc going until another pulse is applied upon pressing the torch push-button. The 
following will then occur: 
4.  Current starts falling. 
5.  The arc nearly extinguishes itself. 
6.  The post-gas phase starts. 
It a relatively long current fall time was set, and one does not wish to wait for automatic extinction of the arc, another pulse may 
be applied to stop welding at any moment. 
However, if the 2T mode selected, the torch push-button must be kept depressed during arc ignition, current rise and welding, 
and then released to allow current fall and arc extinction. 
This generator uses an inverter of the seventh generation (the latest available, as there are no other single-card technology 
inverters of the same power at 90 kHz) and therefore incorporates the following exclusive capabilities and devices. 

MMA Process

7

Summary of Contents for I100STS

Page 1: ...86 5 16758 7 21 0 18 ...

Page 2: ...ENGLISH 3 ESPAÑOL 9 FRANCAIS 16 TECHNICAL TABLES TABLAS TECNICAS 22 TABLES TECHNIQUES SPARE PARTS LIST LISTA DE PIEZAS DE REPUESTO 23 LISTE DES PIECES DE RECHANGE ...

Page 3: ...rthing the welding circuit In other cases it could involve constructing an electromagnetic screen enclosing the power source and the work complete with associated input filters In all cases electromagnetic disturbances must be reduced to the point where they are no longer troublesome Note The welding circuit may or may not be earthed for safety reasons Changing the earthing arrangements should onl...

Page 4: ... the appropriate welding lens shade MUST be worn to protect the operator s eyes from radiant energy and flying sparks or hot metal 1 2 2 Fire prevention Since electric welding arc produces hot metal sparks and slag precautions must be taken to prevent fire and or explosions Make sure that appropriate fire extinguishing equipment is available in the immediate welding area All combustible materials ...

Page 5: ...nd TIG welding 2 2 SYSTEM DESCRIPTION The power supply is built on a single main board with the control logics on separate interchangeable hybrid boards which give the system a very high degree of reliability and simplify maintenance and service The power module uses an INVERTER working at a frequency higher than 80 kHz with a very low dynamic response time 500 millisecond resulting in an extremel...

Page 6: ...g is not inserted in main outlet then connect welding cables in accordance with polarity indications given by the electrode manufacturer The welding circuit should not be deliberately placed in direct or indirect contact with protection wire if not on piece to be welded If earthing is deliberately made on the work piece by means of protection wire the connection must be as direct as possible with ...

Page 7: ...uitable for TIG welding of inox steel iron and copper Connect the earth cable connector to the positive terminal of the welding machine and the clamp as close as possible to the welding spot making sure good electrical contact is made Use the special TIG torch for HF and connect the power connector to the negative terminal of the welding machine The welding circuit must not be put into direct or i...

Page 8: ...e cycle if an arc is not ignited within about fifteen seconds WARNING Do not use commercial igniters After welding do not forget to switch off the welding machine off and shut the gas cylinder valve 4 3 1 ELECTRODE PREPARATION It is necessary to use special attention when preparing the electrode tip grinding it so as to obtain vertical makings as shown in figure see in schemas section CAUTION HOT ...

Page 9: ...municaciones teléfonos radio televisíon o a los sistemas de control y de seguridad Leer con atención estas instrucciones para eliminar o reducir al mínimo las interferencias ATENCIÓN la soldadora ha sido proyectada para trabajar en ambientes industrial por esta razón por utilizarla en ambiente domesticós puede ser necesario observar algunas precauciones para evitar posibles interferencias electrom...

Page 10: ...ciones Las protecciones de los cables y de las maquinaria que se encuentran en el area de trabajo pueden reducir las interferencias La protección de toda la instalación de soldadura o corte puede considerarse adecuada en caso de aplicaciones especiales ISTRUCCIONES PARA EL USO Para un eso correcto de la soldadora es muy importante seguir las indicaciones que hay aquí bajo No exponer a estillicidio...

Page 11: ... arco y por lo tanto producir gas fosgeno Los contenedores de estos solventes así como de otras substancias desegrasantes no tendrán que hallarse cerca del arco de soldadura Los metales cubiertos o los que contienen una significativa cantitad de Plomo Cadmio Cinc Mercurio y Berilio pueden producir concentraciones nocivas de gases tóxicos cuando están sometidas a procedimientos de soldadura al arco...

Page 12: ...tas normas x EN60974 internacionales x S N Número di matricula que tiene que ser mencionado siempre por cualquier pedido referente a la soldadora x Convertidor estático de frecuencia monofase trasformador rectificador x Característica descendiente x MMA Apto para la soldadura con eléctrodos cubiertos x TIG Apto para soldadura TIG x Uo Tensión secundaria sin corriente de soldadura x X Factor de ser...

Page 13: ...NTROL Sobre el panel frontal de la soldadora se pueden ver 1 Potenciómetro de regulación de corriente de soldadura 2 Enchufes por pinza y masa 3 Unico indicador led bicolor A con el color verde indica funcionamiento en corriente de soldadura B con el color rojo indica anomalías tensión alimentación fuera de los límites máximos admitidos de o 10 sobre 220V nominal o intervención de los dispositívos...

Page 14: ...ue todavía es caliente Después de algunos segundos si se cierra la válvula totalmente el flujo del gas se parará Acabada la soldadura no olvidarse de desconectar el aparato y cerrar la víalvula de la bombona del gas TIG HF Esta soldadora puede soldar con procedimiento TIG el acero inoxidable el hierro y el cobre Conectar el conectador del cable de masa con el polo positivo de la soldadora y el bor...

Page 15: ...das las funciones del generador sin causar inconvenientes Procedimiento TIG Encendedor de alta frecuencia completamente electrónico y en estado sólido sin los platinos de descarga todavía utilizados en algunos encendedores anticuados y con muy baja emisión de interferencias Dispositivo de seguridad que desconecta el encendedor y pone en cero el ciclo después de aproximadamente 15 segundos si no se...

Page 16: ...torisée suffisamment compétente pour déterminer si la modification augmente le risque d accident c est à dire en créant des voies parallèles de retour du courant de soudage qui peuvent endommager les circuits de masse d autres appareils EVALUATION DE LA ZONE DE TRAVAIL Avant d installer l appareil de soudage l utilisateur doit évaluer les éventuels problèmes électromagnétiques dans la zone environ...

Page 17: ...d extinction est toujours disponible dans la zone de soudage Tous les matériaux combustibles doivent être éloignés de la zone immédiate de soudage à une distance d au moins 10 mètres Il ne faut jamais souder à l arc des conteneurs vides qui ont contenu des matières toxiques ou explosives Ces conteneurs doivent être soigneusement nettoyés avant le soudage Ne jamais souder dans une atmosphère conten...

Page 18: ...d alimentation est constitué d une seule carte mère les logiques de commande se trouvant sur d autres cartes hybrides interchangeables qui donnent au système un très haut niveau de fiabilité et facilite la maintenance et l entretien Le bloc d alimentation utilise un ONDULEUR fonctionnant à une fréquence supérieure à 80 kHz avec un temps de réponse dynamique très faible 0 5 microsecondes ce qui se ...

Page 19: ...s des câbles pour l électrode et la prise de masse 3 Un voyant lumineux bicolore A Vert indique que le courant de soudage fonctionne B Rouge indique un défaut d alimentation tension hors de la plage 0 10 de 220 V ou une surchauffe 4 2 SOUDAGE PAR ELECTRODE ENROBEE Tous les modèles convient pour le soudage avec tous les types d électrodes Pour les électrodes de cellulose AWS 6010 voyez le tables te...

Page 20: ...née de la torche l écoulement du gaz peut continuer après que la soudure a été réalisée pour protéger l électrode tant qu elle est chaude Après une durée appropriée quelques secondes le gaz peut être fermé en tournant le robinet sur la poignée de la torche Lorsque le soudage est terminé mettre l appareil hors tension et fermer le robinet d arrivée de gaz sur la bouteille TIG HF Cet appareil de sou...

Page 21: ...ilisateur commencerait la phase de soudage le dispositif rétablira automatiquement toutes les fonctions du générateur sans aucun inconvénient Procédé TIG Allumeur à haute fréquence totalement électronique et à l état solide sans les pointes de décharge utilisées encore sur quelques allumeurs archaïques et à une émission de brouillage très basse Dispositif de sécurité qui déconnecte l allumeur et m...

Page 22: ...1 Insulation class H Dimensions cm 12X30X21 Weight Kg 3 5 Electrodes diameter 3 25 Electrodes type R B I Duty cycle 60 200 A Main voltage 230 VAC Frequency 50 60 Hz Cos φ 0 99 Efficiency 0 85 Current range 1 140 A Off load voltage 60 V Output current 100 110 A Output current 60 140 A Absorbed power 100 3 5 KVA Absorbed power 60 4 7 KVA Main current 100 17 A Main current 60 22 7 A Protection class ...

Page 23: ... E8700R16 Cooling fan E8200004 Cooling fan grid 92x92 E9500GN4 Impulse transformer E6900160 T3 Auxiliary transformer E6910019 T2 DUTY CYCLE 80 100 DESCRIPTION CODE POINT OF REFERENCE Varistor 275 V E1700275 VR1 Input bridge E3100060 P1 Electr Capacitor 470uF 400V E4456470 C1 C2 C3 C4 Start resistor 2 2 OHM E2620022 R1 Start relay E8125512 RL1 Auxiliary transformer E6910019 T1 1000PWM hybrid E9220P...

Page 24: ... UF2QH LV D GLYLVLRQ RI QWHUQDWLRQDO QGHSHQGHQFH U 7DXQWRQ 0 3K D ZZZ DUF ZHOGVDIH FRP ...

Reviews: