Attaching the operating instruments

The operating instruments are connected to the instrument
connection ports A, B, C, D, E and F (see section 22) on the
front of the unit. The ports are colour coded and mechanically
coded, so there is no possibility of connecting the instruments
incorrectly.

Blue

A

Phaco handpiece connection

Red

B

Diathermy/HF CUT
connection

Green

C, D

Connection for electrically-
operated vitrectomy
instruments

Luer

E, F

Connection for pneumatically-operated

vitrectomy instruments. They must be connected in
accordance with the instructions on the packaging insert.

To insert, hold the instrument plug by the sleeve with the
coding ridge facing upwards, and plug into the port. The
plug auto-locks in position to prevent dislodgement by a
pull on the cable.

To remove, hold the plug by the sleeve and pull out.

7.1

Suction/rinsing instrument

Plug the irrigation tube (i) and the aspiration tube (a) into
the I/A handpiece. The luer connectors are designed so
that it is impossible to connect the instruments wrongly.

Attach the chosen tip. Wet the tip with irrigation fluid to
ease insertion.

7.2

Ultrasonic phaco handpiece

Reusable tip

Screw an "Excellerator 2" titanium tip onto the handpiece
using the key supplied. Push the key over the tip as
shown in the diagram, and tighten in a clockwise
direction using light axial pressure.

Single use tip

Screw the tip with the pre-mounted key onto the
handpiece. Remove the key and keep it, it will be used
again to remove the tip after the procedure.

Screw a silicone infusion cap VV 603200 or VV 603202
onto the handpiece over the tip until the phaco tip
protrudes by about 1 mm. Wet the silicone cap with
irrigation fluid firstly to simplify attachment.

Plug the irrigation tube (i) and the aspiration tube (a) into
the phaco handpiece. The luer connectors are designed
so that it is impossible to misconnect the tubes.

I/A tip

I/A handpiece

Phaco-Key

Titan-tip

Handpiece

Silicone infusion cap

Summary of Contents for OS3

Page 1: ...29 05 09 VV016011E 1 Operating Instructions OS3 Base unit VC830100 VV016011E Phaco Emulsification System 0297...

Page 2: ...taltic operation 13 8 2 3 Infusion pressure IOP 13 8 2 4 Continuous irrigation 14 8 2 5 Reflux 14 8 2 6 Proportional Override 14 8 3 Ultrasonic phaco 14 8 3 1 Phaco test 14 8 3 2 Phaco operation 14 8...

Page 3: ...may be impaired or the pacemaker itself damaged If in doubt the cardiology department must be consulted 2 The functioning of other electro medical equipment may be affected during the operation of bip...

Page 4: ...k green arrow buttons immediately beneath the display The lower half of the control panel houses the displays and adjustment buttons for the irrigation aspiration system The lowest row on the control...

Page 5: ...g factor can be changed see 8 3 4 PULSE button Switches on pulse or burst operation for phaco 1 2 3 and switches it off when the button is pressed again If the button is held down the pulse or burst p...

Page 6: ...tween positions 0 1 2 and 3 If the pedal is pressed slowly the settings 0 3 can be felt as a slight resistance This resistance can be changed in ParaProg low medium high The pedal is brought to positi...

Page 7: ...ear Linear instrument control Aspiraton Phaco VIT DIA LOW linear CAPS REGULAR fix VISCO INJECTION linear Reflux Instant diathermy Pulse on off linear phaco Pos 3 Instrument Phaco VIT DIA CAPS Override...

Page 8: ...the installed software appears in weakly illuminated lettering The unit is now ready and can be prepared for the operation 5 1 Replacing fuses Press the clip on fuse holder P to the right until it pop...

Page 9: ...trument connection tubes must be kept in the sterile area The sterile person must not insert the tubes into the unit Turn the cassette rotary switch in an anti clockwise direction and open the cassett...

Page 10: ...P button twice 6 3 Removing and cleaning the cassette 6 3 1 Cassettes for single use Fig 3 4 Remove the tubes from the instruments and join together connections 1 and 2 to prevent the liquid from drip...

Page 11: ...g the irrigation tube i and the aspiration tube a into the I A handpiece The luer connectors are designed so that it is impossible to connect the instruments wrongly Attach the chosen tip Wet the tip...

Page 12: ...CO1 PHACO2 PHACO3 CMP1 CMP2 CMP3 as well as VIT A VIT B and VIT PN or VIT A1 VIT A2 etc Calling up values Press the above buttons briefly to call up the stored values immediately Storing new values Pr...

Page 13: ...03 or VV 630010 are being used you can change between the venturi and peristaltic pump at any time To do so the pedal must be in the zero position Effect the change by pressing the venturi button on t...

Page 14: ...be tested before beginning the operation To do so fit a filled test chamber to the handpiece and press the TEST button Never carry out the TEST procedure whilst the handpiece is in the eye NOTE The te...

Page 15: ...ional to the pedal deflection Note CMP1 2 3 have their own memories By holding down the corresponding button phaco 1 2 3 see 8 1 for a short period all settings will be memorized 8 3 5 Occlusion Mode...

Page 16: ...ains available without having to set the unit to diathermy mode by pressing the DIA button This function can be set to DiaLOW or DiaHIGH or switched off in ParaProg NOTE ParaProg can be used to determ...

Page 17: ...nd 3 Duallinear vitrectomy This operating mode enables separate control of the pump by vertical pedal movement and control of the cutting rate by moving the pedal horizontally to the left or vice vers...

Page 18: ...es Every surgeon develops his own preferred operating technique which also requires corresponding specific setting values for the various stages of the operation The OS3 unit can optimally accommodate...

Page 19: ...are temperature 134 C 138 C min cycle time 3 minutes When the instruments are removed from the sterilisation system they must be cooled to room temperature before commencing an operation The instrume...

Page 20: ...itrectomy 200Vss at instrument input Aspiration flow 0 50 ml min 25 Vacuum 0 600 mmHG 10 0 80kPa 10 Noise level 70 dB A Dimensions 380 x 150 x 340 mm W H D Weight Unit 14 8 kg Pedal 4 8 kg Transport a...

Page 21: ...heel System ready The self test has been completed successfully Check tip The tip is not properly attached See Section 8 3 1 Call Service Error 1 Contact service Internal voltages defective The unit c...

Page 22: ...aco accessories included Vitrectomy accessories included 18 Calibration and maintenance Provided that the cassettes are replaced regularly in accordance with the instructions in the packaging this uni...

Page 23: ...nnection NIST EN 397 L Slot for smart card see service manual M1 Pedal port M2 Reserve port M3 Control panel port N Serial interface see service manual O Mains connection socket P Fuse holder Q Mains...

Reviews: