Troubleshooting
User Manual Chemical centrifugal pumps with mechanical seal V080716
31
9
Troubleshooting
9.1
Solve problems
If the product does not function correctly, consult the table below to see if you can
solve the problem yourself. If not, contact your supplier.
/i
WARNING
Disconnect and lock the power supply to the product before any work
is carried out on the product.
Problem
Possible cause
Solution
Electric motor of
product does not run
Power of mains is not
sufficient
Wrong electrical connection Check the electrical
connection. See §
Not all phases are
connected
Check the electrical
connection. See §
Connection is okay but no
power
Check the safety protection.
Fuse is blown
Check the electrical circuit on
short circuit. Replace the fuse.
Product makes noise
or vibrates too much
The fan runs against the
cover of the motor
Bearings are worn or
jammed
Replace the bearings.
Bolts between pump and
motor are not tightened
Tighten the bolts with a
spanner. Apply the correct
torque. See the instruction
card.
Suction and discharge line
are not supported correctly
Make sure the connections are
free of tension.
The interior side of the
product is dirty
Clean the product.
Product is running on a
wrong operating point
Check the specifications of the
liquid and product.
Motor and pump are not
aligned properly
Realign the product.
Wrong connection piece is
used
Use the correct connection
piece.