Correctly install the SAE 3/8′′ liquefied gas pipe on the back of the water heater. 
Correctly connect the volt power cable to the power cable on the back of the water 
heater. 
Red is positive, black is negative; connect the line controller with the two blue lines 
on the back of the water heater, it is not necessary to divide the positive and negative 
poles; pay attention to the water pipe, trachea, and wires on the back of the water 
heater to leave enough length to pull the water heater from the mounting hole. See 
FIG.10. 
Installation of wiring and wired controller must be installed by professional person,
service company or gas water heater suppliers.

The paste should be flat and connected seamlessly. (Be careful not to be too thick) 
Then press this product into the opened hole. 

The water heater flange cover is glued with 18mm wide single-sided adhesive 
anti-flaming EVA. 

18mm anti-flaming EVA

10

DC 12V

Please use DC 12V RV battery

Gas inlet SAE 3/8"

Water outlet G 1/2''

Water inlet G 1/2''

This water heater is designed for RV users. The working voltage is DC 12V RV 
battery and the gas source is propane.
Excessive force will damage the water heater's cold water and hot water 
connections. When installing the gas joint, tighten the joint with two wrenches to 
avoid damaging the water heater joint.

DANGER!

Summary of Contents for FOGATTI FS06B1

Page 1: ...Make A Difference 卓 尔 不 凡 WATER HEATER FOGATTI CN EN 即热式燃气热水器 安装和使用说明书 Installation and Operating Instructions RV Instantaneous Gas Water Heater ...

Page 2: ...用和安全要求 目 录 2 3 5 6 18 22 21 23 24 23 24 27 18 9 19 11 20 12 16 13 17 28 28 29 30 2 0 安全说明 3 0 功能介绍与说明 4 0 安装说明 12 0 保修卡 5 0 操作说明 7 1 日常检查 7 3 设定最小热负荷 8 0 排水和存储说明 9 0 防冻系统 10 0 保修通知 11 0 包装清单 5 1 启动设备 4 1 型号和规格 5 2 线控器说明 4 2 外观 5 3 设定水温的步骤 4 3 零部件 4 5 检查步骤 4 4 安装步骤 4 6 电路接线图 7 0 保养 6 0 故障判断与处理 7 2 维护说明 7 4 备件 3 1 0 安全符号说明 ...

Page 3: ... 气 水供给 可自行行驶或由另一辆车牵引行驶 为防止火灾或爆炸事故的发生 不要在热水器和排烟 口附近放置易燃 易爆 易挥发的物品 在热水器运行期间和使用后 排烟口及其周围部件的 温度较高 请勿用手触摸 以免烫伤 不管是淋浴还是盆浴 为了防止烫伤 应先用手测试 水温 水温合适后再使用 请勿以任何方式改装热水器 自行改装很危险 并且 将不在保修范围内 长期不使用热水器时 为防止热水器水路冻裂及漏气 应排尽机内存水 并关闭进水阀 燃气及电源 环境 温度低于 0 时 必须排出热水器内的水 或者接通 电源并打开燃气阀启动防冻功能 做好防冻处理 具 体操作内容见说明书相关章节 使用期间 按照此手册中指示定期保养 请经常检查 排烟口出口处和进气口是否有堵塞 是否有积雪积冰 尘土污垢 确定热水器能吸入清洁空气 并能将燃烧 产生的废气顺利排放 ...

Page 4: ... 否则请勿高压通电测试 车辆行驶时请勿使用热水器 车辆加油时请勿使用热水器 并关闭热水器电源 烟气排放时注意保护周围建筑物 请勿将热水器和其他设备的排气系统连接 安装时 确保热水器底部平行于水平面 使用热水器时 请选择较平坦的地势停放 车辆 不得使用非我司提供的配件 撤离所有人员离开车辆 关闭燃气气源 请勿使用车辆的任何电器或电话 不要启动车辆的发动机或发电机 请联系最近的授权维修服务商或燃气供应商进行维修 如果您无法联系授权维修服务商或燃气供应商 请与最近的消防队联系 在修复气体泄漏之前 请勿打开气源 禁止在有水的环境中使用 禁止用于室内加热 禁止在可移动式住宅中使用 禁止在装载食物的货车或路边食物贩卖小车中使用 禁止在建筑拖车中使用 禁止用于泳池水加热 如果闻到煤气味该怎么办 禁止使用 危险 危险 ...

Page 5: ...想象 以满足对舒适的要求 低水压启动 启动水压低 使用更方便 熄火保护 热水器在使用过程中意外熄火时 可自动切断燃气供应 确保燃气不会 泄漏 无极变速抗风阻功能 当烟道堵塞或排烟受阻时 内置微电脑系统检知后会适当提 高风机的运行速度 消除有害气体的产生 当速度达到预定的上限转速肘 微电脑 系统发出停气 停火指令 有效地保障安全 水气联动控制 当进水供应中断或关闭出水阀时 热水器会自动停止燃烧并关机 出水温度显示 带出水温度显示功能 防冻功能 当热水器内水管温度低于 6 1 43 2 时 线控制器将显示 Fd 字符 热水器将启动点火并在一定负荷下运行 整机运行 5 秒后自动关闭 或 2 秒 内热水器水温达到 32 1 90 2 热水器将自动关闭 关机后等待 3 分 钟热水器再次自检 当温度低于 6 1 43 2 或防冻温控器闭合时又再 次运行 如此循环 在启动防冻功能的过程中 当发生故障时 ...

Page 6: ...权安装服务的公司进行安装和维修 否则对因安装 维修而导致的 事故 我公司概不负责 必须正确安装热水器以保证进气百叶窗和排烟管始终空气流通无阻碍 在对系统进行压力测试时 设备应与供气管道系统断开连接 请将该产品的任何部件放置在儿童无法接触到的地方 避免发生人身伤害 勿将该产品安装在悬垂结构下 应安装在牢固的车体位置上 安装该产品时 确保排烟口不会被车门遮挡 如果情况不允许 请确保车门打开时 热水器通风口与车门之间留出至少 160mm 的距离 以下说明适用于房车燃气热水器 如果您对特定安装或应用有其他疑问 请咨询我司或 我司授权公司进行安装维修服务 危险 危险 01 限制开门角度 ...

Page 7: ...Make A Difference 卓 尔 不 凡 CN 7 如果墙体不是耐火材料 该产品的背面和四周与可燃材料之间的缝隙必须填充隔热阻 燃材料 由于乙烯壁板的差异 在没有事先咨询壁板制造商时 该设备不应安装在乙烯墙板上 当热水器排烟口距离门窗小于 305mm 时 请勿安装在该位置 305mm 305mm 02 热水器的安装位置应高于地面305mm以上 305mm 03 ...

Page 8: ...篷 折篷或任何其他外壳覆盖的区域 热水器可安装在房车的可伸缩遮阳篷下 但遮阳篷必须通风良好 热水器必须直立安装 否则会影响热水器的正常使用 安装热水器时 应确保接地可靠 进水管与出水管连接前 请将水管内冲洗干净 在水泵后面要装一个易组装的过滤网 用于过滤水质 如果没有过滤网 我司将不提 供保修服务 阀门应安装在燃气管道 进水管和出水管上 便于维护和保养 安装后检查漏气和漏水 确保没有任何气体和水泄漏 从排气口到易燃物的最小距离应 1000mm 如果安全阀定期排放 这可能是由于供水系统中的热膨胀压力过大造成的 请联系供水 商或当地管道检查员纠正这种情况 不要堵塞安全阀 危险 04 ...

Page 9: ...个混水阀 在额定设置下 出水温度不会超过 51 当水流量偏小或进水温度过高时 热水器有可能将水加热到 51 以上 此时 请打开混水阀调整至舒适的淋浴温度 危险 危险 锋利的边缘会导致割伤和伤害 12kW 6 通用液化石油气 气体 输入负荷 喷嘴数量 最大工作水压力 标称燃气压力 喷嘴尺寸 最小工作水压力 水加热能力 温 度上升 25K 输出负荷 最高水温 标称分气杆压力 电源 0 91MM 12VDC 10amp 51 10 8kW 6L min 0 1MPa 2 8kPa 0 8MPa 1 3kPa 热水器型号 FS06B1 4 1 型号和规格 ...

Page 10: ...CN 10 进气口压力测试 在热水器的入口接头处安装一个带压力测量喷嘴的接头 压力测量 喷嘴的尺寸是外部直径 6mm 内径不大于 1mm 从压力测量喷嘴测量气体压力 见 图 05 气体歧管入口压力测试 如图所示 打开门 取下压力测量喷嘴的密封螺钉 并测量 压力测量喷嘴的气体压力 见图 06 气压实验位置 05 06 ...

Page 11: ...Make A Difference 卓 尔 不 凡 CN 11 4 2 外观 07 装饰圈 平面锁 进气格栅 请使用 DC 12V 房车电池 进气口 G 3 8 出水口 G 1 2 进水口 G 1 2 ...

Page 12: ...CN 12 4 3 零部件名称 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 08 ...

Page 13: ...线控器 防冻温控器 防尘网 进水管总成 燃烧器 1 16 2 17 3 18 5 20 15 7 22 4 19 6 21 10 25 11 26 14 13 28 12 27 8 23 9 24 序号 序号 名称 名称 4 4 安装步骤 不要将热水器安装在房车的通道中 应安装在房车的外墙上 排气口朝向房车外部 热水器应安装在坚固的框架上 为了牢固地安装热水器 设备的底部应由不易燃的地板或框架支撑 如果安装开口的周围是可燃材料 则需使用阻燃绝缘材料 例如隔热毡或隔热板 以 使热水器的后侧与可燃表面完全分离 填充材料的最小厚度必须大于 20mm 热水器后面的外壳连接间隙应在安装过程中用耐高温密封胶密封 将其与房车内部空 间隔离 以使燃烧的空气来自房车外部 燃烧产生的废气排到车外 安装前请在房车上选择合适的安装位置 ...

Page 14: ...部或后部 请预留燃气管 进 出水管 电源线和其他管线通道孔 应预留足够的燃气管道 电线 水管的长度 推荐大于开口深度的 1 5 倍 以便维护和 测试 孔的四周应确保足够的强度来固定热水器 见图 09 在热水器下方增加支撑框架可以增加牢固性 以确保热水器不会因车辆的加速或停止 而造成损坏 在热水器背面正确安装 G3 8 液化气管 将电源线正确连接到热水器 红色是正极 黑色是负极 将线控器与热水器背面的两条蓝线连接起来 不区分正负极 注意热水器背面的水管 燃气管和电线 需留出足够的长度将热水器从安装孔中取出 见图 10 必须由专业人员或燃气热水器供应商安装接线 线控器等 ...

Page 15: ...燃气接头时 请用两把扳手拧紧接 头 以免损坏接头 危险 粘贴处应平整 无缝隙 注意不要太厚 然后将该产品放入开孔中 用 11 个螺钉 ST5 25mm 将热水器固定在车体上 开孔处应与水和空气隔绝 以防止进入房车内部 见图 11 在热水器法兰盖上粘贴 18mm 宽的单面粘合阻燃 EVA 板 线控器和热水器之间的连接应根据具体环境合理布局 使用提供的两个螺钉 2 ST4 25 固定线控器底座 并将线控器放入座内 见图 12 选择一个方便操作的位置来放置线控器 10 11 18mm 阻燃 EVA 请使用 DC 12V 房车电池 进气口 G 3 8 出水口 G 1 2 进水口 G 1 2 ...

Page 16: ...区域 热水器可安装在托车内或可伸缩遮阳篷下 但遮阳篷必须通风良好 该燃气热水器适用于符合标准的 9 8Kgs 液化气钢瓶 YSP23 5 规格 9 8kg 外形尺寸 Ø 314 526mm 安装人员在确认任何气体连接之间没有发生泄漏后 应检查热水器的运行情况 步骤参 见第 17 页 检查燃气管线有无泄漏 将肥皂水涂抹到连接处 看是否有气泡 如果没有 则表示没有泄漏 如果有气泡 请再次安装 检查水路有无泄漏 4 5 检查步骤 注意 房车热水器配有水压安全阀 如果进水压力过高安全阀就会启动 将水排出泄压 以保护水管免受高压损坏 12 ...

Page 17: ...Make A Difference 卓 尔 不 凡 CN 17 4 6 电路接线图 13 DC 12V ...

Page 18: ...一个混水阀 在额定设置下 出水温度不会超过 51 当水流量偏小或进水温度高时 热水器有可能将水加热到 51 以上 此时 请打开混水阀调整至舒适的淋浴温度 首次操作前 请拆除包装材料 如塑料袋 塑料密封胶带等 包装材料可能会堵塞 热水器的出口 危险 5 1 启动设备 5 0 操作说明 注意 在电器运行时请勿在该产品附近喷洒喷雾剂 注意 请勿在该产品内或附近使用或存放易燃物品 注意 该设备上方及周围请勿放置物品 注意 请勿改装该设备 用户在初次使用前确认热水器是否安装正确 仔细检查连接是否正确并且有无泄露 确 认后 请按照以下步骤操作 14 电源 开关 DC 12V 进气口 出水口 入水口 ...

Page 19: ...非由监护人陪同 否则不建议儿童和青少年自行操作热水器 使用设备时请保持车门关闭 为了确保该设备的安全 必须按照制造商的说明进行安装 操作和维护 在安装热水器之前 必须安装一个混水阀 在额定设置下 水温不超过 51 当水 流量偏小或进水温度高的时候 热水器有可能将水加热到 51 以上 此时 请打开 混水阀调整至舒适的淋浴温度 没有监护人的指导 儿童不得操作此热水器 该机器的任何部件都应存放在儿童无法触及的地方 在阅读说明书之前 请勿操作该产品 请勿在该设备上放置物品 请勿在该产品附近存放化学品或易燃材料 或喷洒喷雾剂 请勿将面板 盖子或防护装置从设备上拆卸下来操作 危险 危险 危险 5 2 线控器说明 关机或断电后 热水器会自动切断燃气供应 用户在停电或关机时应关闭燃气阀 请在 下次启动前检查 DC12V 的电源连接 ...

Page 20: ... 如果发生故障将显示故障代码 当系统通电或有效操作时蜂鸣器均发出 哔 一声 系统发生故障时蜂鸣器连续发出 10 次 哔 声 每次间隔 1 秒 使用完毕后 请按 关闭热水器 同时关闭燃气和供水 该机出水温度设定范围为 35 51 设计出水温度不超过 51 123 每按一下 按键 温度上升 1 持续按上升键 温度每 0 25 秒上升 1 每按一下 按键 温度下降 1 持续按下降键 温度每 0 25 秒下降 1 5 3 设定水温 请勿在该设备或任何其他设备附近存放或使用汽油或其他易燃蒸气和液体 危险 15 C F ...

Page 21: ...分钟后自动恢复正常使用 关水等水流信号消失或断电重启可立 即恢复使用 出水温度探头开路或短路 请检查出水温度探头连线或更换连线 点火前检测到有火焰信号 蜂鸣警报提示故障 需断电后清除故障 风机故障 开机或热水器工作过程中检测不到风机信号 正常燃烧中 风机转速连续五秒超出设定最高转速值 热水器设定定时器时间到 nE 设定为打开 故障报警解除和复位方法 点火故障 点不着火或工作过程中出现意外熄火 请检查燃气是否正 常供给 检查正常后再使用 温控器发生故障 开机或热水器工作过程中检测到温控断开 检查温 控器连线或降低水温 进水温度探头故障 进水温度探头开路或短路 请检查进水温度探头 连线或更换连线 正常燃烧前 主阀开路或短路 比例阀开路 正常燃烧中 主阀开路或短路 比例阀开路 过热故障 当水温连续 3 秒在 60 140 以上时 显示屏将显示错误代码 请检查供水压力是否过低 E0 E2 E5 E...

Page 22: ...温过低 水流超过热水器的加热能力 此时请将水量适当 调小 从热水器到热水阀门有一段距离 因水管内有残留冷水 故 需要等待一段时间 待残留的冷水流出后才能出热水 管道 的距离越远 需要等待的时间越多 热水太小不能启动热水器 水就会变冷 需要达到热水器的 最小运行流量才能保证热水器稳定运行 为了防止缺氧 部分机型号具有 20 或 40 分钟定时保护功能 请关闭水龙头并等待一段时间后再使用 这是风机有延迟停机的功能 为了将热水器中的废气彻底排 放干净 以保证用户的安全 打开热水器机箱门确定机箱内开关已打开并且保险丝完好 如保险丝烧断 请更换相同规格的保险丝 保险丝 10A 125V 排气口冒白烟 热水开太小变成冷水 冬天未能提供高温热 水 20 分钟或 40 分钟后 热水器突然熄灭 关闭热水阀 但风扇 不能立即停止 打开热水阀门不能立 刻出热水 整机通电后线控器无 响应 现象 原因和处理方法 ...

Page 23: ...学洗剂和挥发性溶剂 以免外壳变色 定期清理进气格栅 防尘滤网 排烟口上的灰尘 以保证进气和排烟通畅 进气滤网 装在进气格栅背面 需要开机箱门 拧掉四个手拧螺钉 取下进气滤网 用清水清洗 干净后再装回原处 关闭热水器进水 卸下热水器背部的进水管 将进水接头滤网清洗干净 保证水路通畅 再将进水管接回去方可重新使用热水器 定期排放房车系统中的水 并用经过认可的除垢溶液冲洗热交换器 具体请参考房 车供应商提供的说明书 使用拧干的湿布擦拭显示屏 不要使用汽油或油脂性洗涤剂 以免引起变形 23 7 1 日常检查 7 2 维护说明 保持设备区域清洁 不含可燃物质 汽油和其他易燃蒸气和液体 如果发生过热或气体供应无法关闭的情况 请手动关闭气体控制阀 小心 维修控制器时 在断开连接之前标记所有电线 接线错误可能导致操作不当 和危险 维修后验证操作是否正确 ...

Page 24: ...法 1 方法 2 插电后 显示屏显示 O 按 持续 3 秒 显示屏显示 PP 按 显示 FA 按 显示规格 将值设置为 00 按 退出 按 显示 PH 按 显示 PL 然后打开气体和水 热水器将以最小的热负荷运行 按 切换 PL dH FH FL 等规格 直至显示 qu 然后按 保存并退出设定 将线控器上的温度设置为 35 如果进水温度高到足以使出水温度高于 35 则证明 热水器在最小热负荷下运行 平面锁 燃气比例阀 直流风机组件 燃烧器 部分 图片 ...

Page 25: ...Make A Difference 卓 尔 不 凡 CN 25 点火针组件 火排阀体连接管 进气管总成 线控器 进水管总成 保险丝 125V 10a 风压开关 部分 图片 ...

Page 26: ...CN 26 水流传感器 超温保护温控器 进水温度探头 防冻温控室 出水温度探头 控制器 进水滤网 部分 图片 ...

Page 27: ...水前需先关闭电源 燃气阀 应用较小压力的压缩空气 小于 2bar 当热水器管道内的水排干净后即可 关闭压缩空气阀门 c 切勿长时间用压缩空气排水 否则会损坏热水器内部零件 关闭热水器电源 供气 供水系统上的压力泵 打开热水器冷热水龙头 按照房车制造商的说明排空整个水路系统中的水 冬季必须排干热水器中的水 以防结冰 注意 房车供水系统重新注水时 所有空气从管线中排出后再启动热水器 注意 排水管必须将热水器排出的水排放到房车的外部 安全阀和热水器之间不得设置阀门 出现泄压时 安全阀的排放将被引导到合适的 地方进行排放 并且排放管线中不安装减压或其他限制装置 此外 排放管的安装 应确保阀门和管道内的水可以完全排空 危险 DC 12V 16 ...

Page 28: ...过程中 出现故障时 则报告相应故障以及显示对应代码 过 15min 后 系统自动清除故障代码 若仍满足防冻启动条件 则再次启动防冻功能 尊敬的用户 感谢您使用我公司产品 我公司将按照 中华人民共和国消费者保护法 的相关规定为您提供优质的服务 排水防冻 适用于较长时间不使用该机的情况 有关具体操作 请参阅 排放和 存储说明 添加房车制造商推荐的防冻剂防冻 启动防冻功能防冻 打开电源开关和燃气阀 关闭进水阀时热水器系统将默认进入 防冻模式 确保房车内有足够的燃气可供使用 为确保您的利益 请仔细填写保修卡 此保修须知仅适用于我司燃气热水器产品 凡购买我司产品的用户 如产品因质量问题发生故障 可凭有效购买证明 到我司 进行保修 我公司各产品保修期限为 以购机证明开具日期起计算 强排机保修 一年 终身维修 请勿用于商业用途 否则会缩短产品的使用寿命 如果用于商业用途 即使产品在 保修期内我们也将收取...

Page 29: ...产品 有效购机证明经涂改的产品 由于电压不稳定或超出正常电压范围 DC 12V 或电源线路安装不符合国家电器 安装要求而造成损坏的产品 此说明书提到的不宜使用的以及因使用方法不当而造成损坏的产品 根据国家相关标准规定 人工煤气型燃气热水器使用年限 6 年 天然气 液化气机型 热水器使用年限为 8 年 如果产品超过了国家规定的使用寿命 发生故障时 我公司 不再提供相关修理服务 请参照国家相关废旧家电报废规定或政策对产品进行更新换 代 旧机应进行报废处理 不得再流向市场销售 以免引起安全事故 a b c d g e f 燃气热水器 1 台 1 本 1 个 11 个 2 个 1 2 3 4 5 螺钉 ST5 25 使 用 说 明 书 含保修卡 螺钉 ST4 25 线控器 序号 物品 数量 备注 ...

Page 30: ...CN 30 12 0 保修卡 ...

Page 31: ...Make A Difference 卓 尔 不 凡 CN 31 ...

Page 32: ... 37 51 57 55 57 58 58 59 62 51 41 53 43 54 44 48 45 49 63 64 65 65 3 0 Function introduction and explanation 4 0 Installation instructions 12 0 Warranty card 5 0 Operation instructions 7 1 Daily inspection 7 3 The way to set minimum heat load 8 0 Drain and store instructions 9 0 Antifreeze system 10 0 Warranty notice 11 0 Packing list 5 1 The steps for starting the unit 4 1 Model and specification...

Page 33: ...s nearby the water heaters and flue exhausted pipe During operation of the water heater and after use the temperature of the flue exhaust pipe and the surrounding components is high Please do not touch any of it with your hands to avoid scalding In the shower or bath in order to prevent scalding you should firstly test the water temperature by hand and then use it after confirming it is suitable f...

Page 34: ...y used by the vehicle mounted gas water heater must be power supply complying with class 2 safety isolated Please use a qualified power supply to avoid damage to the water heater Do not modify the positive grounding system of the water heater Do not test the water heater with high voltage power unless the water heater power switch is turned off Do not use a water heater while the vehicle is in mot...

Page 35: ...he whole process of the water heater Press the key to start the water heater and set the required temperature After the microcomputer intelligent control system detects the qualified water flow it starts the ignition device After that the gas valve is turned on to light the gas burner and then the user can enjoy a steady stream of constant temperature hot water The microcomputer automatically dete...

Page 36: ... outlet valve is closed the water heater will automatically stop the combustion and shut down Outlet water temperature display with outlet water temperature display Frost protection function When the temperature of the water pipe in the water heater is lower than 6 1 C 43 F 2 F the line controller will display Fd character the machine will start ignition and run with a certain load the water heate...

Page 37: ...d to property damage personnel injury or death The product must be installed and repaired by an authorised installation service company otherwise we will not be responsible for any accidents caused by improper installation or maintenance and warranty will be void Australian Standard AS3500 1 Water Services Australian Standard AS3500 4 Heated Water Services Australian Standard AS3000 Electrical Ins...

Page 38: ...t install this product under any overhanging structure such as awnings This product should be installed in any place where the door will not be covered or blocked If the wall is not fire proof the gap between the back of the product and the surrounding flammable structure and combustible materials must be filled with heat proof and flame resistance materials The equipment should not be installed o...

Page 39: ...an 305mm above the ground Do not install the water heater or other electrical appliances in the exhaust port facing an area covered with awning canopy or any other enclosure The water heater can be installed in the trailer or under the retractable awning but the awning must be well ventilated The water heater must be installed uprightly otherwise it will affect the normal use of the water heater 3...

Page 40: ... leakage after installation make sure there is no any gas and water leakage The minimum distance from the exhaust outlet to the flammable surface should be 500mm The gas pressure range for the normal operation of the water heater is that the maximum inlet pressure cannot exceed 3 3 kPa 13 w c and the minimum pressure cannot be lower than 1 99 kPa 8 w c Out of range will not work normally If a reli...

Page 41: ... the water to the likely above 51 At this moment please open the mixing valve to provide you with a comfortable shower temperature DANGER DANGER SHARP EDGES CAN CAUSE CUTS AND INJURY 12kW 6 Universal LPG Gas intended for Total nominal gas consumption Number of injector Max working water pressure Nominal test point pressure Injector size Min working water pressure Water heating capacity temp rise 2...

Page 42: ...meter of 6 mm and an inner diameter of not more than 1 mm The gas pressure is measured from the pressure measuring nozzle See FIG 05 Gas manifold inlet pressure test open the door remove the pressure measuring nozzle sealing screw and measure the gas pressure from the pressure measuring nozzle See FIG 06 Gas pressure test position 42 05 06 gas pressure test nozzle gas pressure test nozzle ...

Page 43: ...Make A Difference 卓 尔 不 凡 EN Exhaust Flat lock Air inlet grilles Water outlet G 1 2 Water inlet G 1 2 Gas inlet SAE 3 8 DC 12V Please use DC 12V RV battery 43 4 2 Appearance 07 ...

Page 44: ...EN 44 4 3 Main parts name 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 08 ...

Page 45: ...pipe Burner 1 16 2 17 3 18 5 20 15 7 22 4 19 6 21 10 25 11 26 14 13 28 12 27 8 23 9 24 NO NO Name Name Do not install the water heater in the RV aisle It should be installed on the exterior wall of the RV The exhaust port should face outside the RV RV hot water heater should be installed on a solid or on a non combustible frame In order to install a water heater firmly the unit s bottom should be ...

Page 46: ...ater pipe when the water heater is pulled out of the hole And at the bottom or back of the hole please reserve space for gas inlet inlet outlet pipe power line and other channel holes Reserve extra gas pipe wire pipe length should be greater than the opening depth 1 5 times for maintenance and testing The perimeter of the hole should ensure sufficient strength to fix the water heater See FIG 09 Th...

Page 47: ...f wiring and wired controller must be installed by professional person service company or gas water heater suppliers The paste should be flat and connected seamlessly Be careful not to be too thick Then press this product into the opened hole The water heater flange cover is glued with 18mm wide single sided adhesive anti flaming EVA 18mm anti flaming EVA 10 DC 12V Please use DC 12V RV battery Gas...

Page 48: ...oller and the water heater should be reasonably laid out according to the specific environment See FIG 12 For example put soapy water on gas connection to see whether there are bubbles If there are no bubbles it means noleakage if bubbles occur please check connections Choose a convenient location to place the Wire Controller Confirm there is no leakage happening between any gas connections 12 4 5...

Page 49: ...kg 8 5kg 4 6 Product wiring diagram The minimum distance from the smoke outlet to the flammable surface should be 500mm Do not install the water heater or other electrical appliances in the exhaust port facing an area covered with awning canopy or any other enclosure The water heater can be installed in the trailer or under the retractable awning but the awning must be well ventilated This RV wate...

Page 50: ...rature probe Wind pressure switch Gas proportion valve Overtemperature protection thermostat Antifreeze thermostat Wired controller DC fan assembly DC 12V Switch Fuse box Water inlet temperature probe Ignition pin assembly ...

Page 51: ...to provide you with a comfortable shower temperature Prior to first operation please remove any packing protection like plastic film plastic bag plastic sealing tapeor any packing material can block the outlet of water heater Confirm that the power switch in the water heater is turned on See FIG 14 After confirming the power is on press the wire controller key Turn on the water inlet valve and gas...

Page 52: ...eater will heat the water to the likely above 50 temperature At this moment please open the mixing valve to provide you with acomfortable shower temperature Children are not allowed to operate this water heater without the guidance of TO BE INSTALLED ON FIRE RESISTANT MATERIAL DO NOT OPERATE THIS APPLIANCE BEFORE LEAK CHECKING HOSES AND GAS CYLINDER CONNECTION SUITABLE ONLY FOR INDOOR INSTALLATION...

Page 53: ...ault alarm the display will change to display fault code The buzzer sound B occurs when the system is powered on or is operating effectively When fault alarm occurs in the system the buzzer sound B B B is issued continuously for 10 times and every one second for each sound After finishing using the water heater please press to turn off the heater water and gas should be turned off at the same time...

Page 54: ...ing this key continuously Each time you press the key the temperature will drop by 1 and the temperature drops by 1 every 0 25 seconds while you keep pressing this key continuously 15 Blower Heat up button Heat down button Celsius display Display setting temperature Display fault code Display water temperature Flame Power indicator Celsius Fahrenheit Switch button ON OFF C F Fahrenheit display Sho...

Page 55: ...2 seconds Water heater set timer time to nE is set to open Ignition failure no ignition Please check whether the gas is supplied normally and check it before use The thermostat malfunctions and the temperature control is detected during the start up or water heater operation The inlet temperature probe is faulty and the inlet temperature probe is open or shorted Before normal combustion the main v...

Page 56: ...mist The inlet water temperature is too low and the water flow exceeds the heating capacity of the water heater Please adjust the amount of water appropriately If the water flow is too low the water will become cold A minimum water flow of 1 gallon per minute is required to ensure the stable operation of the water heater In order to prevent oxygen deprivation some models have 20 or 40 minute timin...

Page 57: ...e is cold water left in the water pipe it will take some time to use the original cold water before the hot water The longer the pipeline is the more time it takes Open the door of the water heater door and make sure the switch inside the door is on and the fuse is intact If the fuse blows replace the fuse of the same size Fuse 10A 125V The hot water valve cannot open hot water immediately After t...

Page 58: ... and flush the heat exchanger with an approved detergent Wipe the display with a damp cloth Do not use gasoline or grease detergents to avoid shape changes When travelling on dusty roads please check and clean the interior of the water heater and blow excess dust away carefully using a compressed air gun Excessive build up of dust can affect the operation of this unit it is your responsibility to ...

Page 59: ...e gas and water Then water heater will run in minimun heat load After testing above press to switch specifications like PL DH FH FL till it shows qu then press to save and exit setting Set the temperature on wired controller to be 95 then if the water inlet temperature is high enough to make outlet water temperature higher than 95 it proves that the water heater is running in its minimum heat load...

Page 60: ...EN 60 Ignition pin assembly The connection pipe of burner and valve Gas inlet assembly Wired controller Water inlet assembly FUSE 125V 10A Wind pressure switch Parts Photo ...

Page 61: ...e A Difference 卓 尔 不 凡 EN 61 Water flow sensor Overtempera ture protection thermostat Inflow temperature probe Antifreeze thermostat Water temperature probe Burner controller Water inlet filter Parts Photo ...

Page 62: ...a tee fitting Turn off water inlet A open water outlet B before draining Turn water outlet D open the compressed air valve C Compressed air blows water out of the drain Note Turn off the power and gas valve before draining Apply compressed air less than 300kPa Close the compressed air valve when the pipe is dry Blowing water for a long time will cause damage to the internal parts of the water heat...

Page 63: ... a fault occurs the corresponding fault is reported and the corresponding code is displayed After 15 minutes the system automatically clears the fault code If the freeze protection start condition is still met the anti freeze will start again 9 0 Antifreeze system No valve is to be placed between the relief valve and water heater The discharge from temperature and pressure relief valves will be vi...

Page 64: ...ns are not within the scope of free warranty service Our company can provide you with paid product services Beyond the validity period of the free warranty time the product can still be used after repair Damage to products caused by improper transportation or storage of the user or failure to operate in accordance with the instructions Disassemble or repair the product without our company s permis...

Page 65: ... number Purchasing date The power supply of the water heater must be reliably grounded and equipped with a leakage protection device to prevent accidental circuit leakage Power outlet connector may be subject to water penetration Use a splash proof power outlet and take care of the joints Water heaters should be used on the RV Do not use indoors Exhaust gas must be discharged outside the vehicle t...

Page 66: ...EN 66 ...

Page 67: ...Make A Difference 卓 尔 不 凡 EN 67 ...

Page 68: ...雷纳科技 深圳 有限公司 保留随时修改价格 材料 规格和型号的权利 或停止任何产品型号的生产 恕不另行通知 All rights reserved ARANA TECH Shenzhen Co Ltd reserves the right to modify at any time without notice prices materials specifications and models or to cease production of any model FS06B1 0619 V01 ...

Reviews: