11
5.3
Bracket fixing
The monitor must be mounted after having fixed the bracket at the desired location (the previous paragraph shows the bracket drilling template).
The bracket must be slid out of the monitor seat (
A
, Fig. 8) and fixed using the supplied screws (
B
).
Make sure the bracket is securely mounted, fit the monitor on it, and push it until it locks in place (
C
).
*
Depending on provided configuration
Fig. 8
WARNING: Delta 80 computer must only be fastened through the supplied bracket, using suitable screws.
NO OTHER TYPE OF FASTENING IS ALLOWED.
ARAG is not liable for damages to the equipment, persons or animals caused by failure to observe the above instructions.
5.4
Control unit (ECU) fixing
Respect the mounting direction of the control units, as specified in Fig. 9 (connectors shall be facing down).
Fix the ECU using the 4 bolts fitted into their slots (
A
, Fig. 9).
No other type of position is allowed.
Fig. 9
5.5
Control unit position
The control unit must be fixed with the special brackets supplied and fitted to the unit, positioning it as shown in the manual provided with the assembly.
MAKE SURE TO FOLLOW ALL THE SAFETY INSTRUCTIONS GIVEN IN THE CONTROL UNIT’S MANUAL.
5.6
Hydraulic unit positioning
The hydraulic unit shall be secured to the machine, making sure it is well protected against the elements and the fluid sprayed by the machine.
ARAG IS NOT LIABLE FOR ANY DAMAGE RESULTING FROM INSTALLATION BY UNSKILLED PERSONNEL. ANY SYSTEM
DAMAGE CAUSED BY A WRONG INSTALLATION AND/OR CONNECTION AUTOMATICALLY VOIDS THE WARRANTY.
WARNING! DO NOT CONNECT HYDRAULIC UNITS OTHER THAN THE SPECIFIED ONES (SEE ARAG GENERAL CATALOGUE).
ARAG IS NOT LIABLE FOR ANY DAMAGE TO THE PRODUCT, MALFUNCTION ERRORS AND ANY KIND OF RISK IF THE MODULE
IS CONNECTED TO NON ORIGINAL UNITS OR UNITS NOT SUPPLIED BY ARAG.
INSTALLATION